1996Pediatric AnesthesiaRequires access

Pressure support ventilation increases cardiac output in neonates and infants

N. Gullberg, Per Winberg, H. Selldén

Open publisher page 19 citations

Abstract

Fifteen neonates and infants were investigated during pressure controlled ventilation (PCV) and pressure support ventilation (PSV) on a Servo 300 ventilator. Changes in cardiac output (aortic mean blood flow velocity) were assessed with the Doppler technique. During PSV cardiac output increased by 16% (P < 0.01) compared with PCV with equal ventilation. Mean airway pressure decreased significantly during PSV compared with PCV, which may explain the increased cardiac output. During PSV, when inspiratory/expiratory (I:E) relations are dependent on the patient, we found a lower I:E ratio compared with PCV. It can be assumed that at least part of the decreased mean airway pressure is caused by the lower I:E ratio. As the heart rate was unchanged, the variations in cardiac output were caused by alterations in stroke volume. It is concluded that a patient triggered mode should be preferred providing that the neonate/infant has the ability to elicit the ventilator's triggering system.

About this research paper

What this paper is about

Fifteen neonates and infants were investigated during pressure controlled ventilation (PCV) and pressure support ventilation (PSV) on a Servo 300 ventilator. Changes in cardiac output (aortic mean blood flow velocity) were assessed with the Doppler technique. During PSV cardiac output increased by 16% (P < 0.01) compared with PCV with equal ventilation. Mean airway pressure decreased significantly during PSV compared with PCV, which may explain the increased cardiac output. During PSV, when inspiratory/expiratory (I:E) relations are dependent on the patient, we found a lower I:E ratio compared with PCV. It can be assumed that at least part of the decreased mean airway pressure is caused by the lower I:E ratio. As the heart rate was unchanged, the variations in cardiac output were caused by alterations in stroke volume. It is concluded that a patient triggered mode should be preferred providing that the neonate/infant has the ability to elicit the ventilator's triggering system.

Why it matters

OpenAlex reports 19 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fifteen neonates and infants were investigated during pressure controlled ventilation (PCV) and pressure support ventilation (PSV) on a Servo 300 ventilator. Changes in cardiac output (aortic mean blood flow velocity) were assessed with the Doppler technique. During PSV cardiac output increased by 16% (P < 0.01) compared with PCV with equal ventilation. Mean airway pressure decreased significantly during PSV compared with PCV, which may explain the increased cardiac output. During PSV, when inspiratory/expiratory (I:E) relations are dependent on the patient, we found a lower I:E ratio compared with PCV. It can be assumed that at least part of the decreased mean airway pressure is caused by the lower I:E ratio. As the heart rate was unchanged, the variations in cardiac output were caused by alterations in stroke volume. It is concluded that a patient triggered mode should be preferred providing that the neonate/infant has the ability to elicit the ventilator's triggering system.

Key concepts: Medicine, Cardiac output, Mean airway pressure, Ventilation (architecture), Stroke volume, Anesthesia, Cardiology, Heart rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Pressure support ventilation increases cardiac output in neonates and infants — Research Paper | ScholarLens