1988International Journal of AudiologyRequires access

Auditory Brainstem Responses as a Function of Average Hearing Sensitivity for 2 000-4 000 Hz

Christopher D. Bauch, Wayne O. Olsen

Open publisher page 15 citations

Abstract

Average hearing thresholds for 2,000, 3,000 and 4,000 Hz and ABR results were analyzed for 290 patients having some degree of cochlear hearing loss. As average hearing sensitivity in the 2,000- to 4,000-Hz range became poorer, the incidence of abnormal auditory brainstem responses (ABR) increased. When the 2,000-Hz threshold sensitivity was 0-40 dB and the three-frequency average hearing loss was less than 50 dB, nearly 80% of ABR tracings were normal. Steeply sloping audiograms above 2,000 Hz increased the percent of abnormal ABR results.

About this research paper

What this paper is about

Average hearing thresholds for 2,000, 3,000 and 4,000 Hz and ABR results were analyzed for 290 patients having some degree of cochlear hearing loss. As average hearing sensitivity in the 2,000- to 4,000-Hz range became poorer, the incidence of abnormal auditory brainstem responses (ABR) increased. When the 2,000-Hz threshold sensitivity was 0-40 dB and the three-frequency average hearing loss was less than 50 dB, nearly 80% of ABR tracings were normal. Steeply sloping audiograms above 2,000 Hz increased the percent of abnormal ABR results.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Average hearing thresholds for 2,000, 3,000 and 4,000 Hz and ABR results were analyzed for 290 patients having some degree of cochlear hearing loss. As average hearing sensitivity in the 2,000- to 4,000-Hz range became poorer, the incidence of abnormal auditory brainstem responses (ABR) increased. When the 2,000-Hz threshold sensitivity was 0-40 dB and the three-frequency average hearing loss was less than 50 dB, nearly 80% of ABR tracings were normal. Steeply sloping audiograms above 2,000 Hz increased the percent of abnormal ABR results.

Key concepts: Audiogram, Audiology, Auditory brainstem response, Hearing loss, Brainstem, Medicine, Audiometry, Sensitivity (control systems)

Related papers

Back to paper searchBrowse research topicsOriginal source
Auditory Brainstem Responses as a Function of Average Hearing Sensitivity for 2 000-4 000 Hz — Research Paper | ScholarLens