Increased Sensitivity Spectrophotometric Flow Analysis Method for Copper Determination in Water Samples
Patrícia S. Peixoto, Ildikó V. Tóth
Abstract
Patrícia S. Peixoto, Ildikó V. Tóth
Abstract
A reverse configured flow injection system was developed for the determination of copper in water samples. In this study, a bathocuproine disulfonic acid copper complexing reagent was used. In the presence of a reducing agent (hydroxylamine), the formation of complex was monitored at 484 nm. The determination range extended from 1 to 40 µg L−1, with an applicable determination rate of 40 h−1. The developed method was applied to the determination of copper in water samples (estuarine, river, and drinking water) and showed good accuracy (z-score below 2). The detection limit of 0.7 µg L−1 copper is consistent with the requirement of the target water samples. The developed method was also used for the comparison of different spectrophotometric flow cells. Alternative flow cells (U, Z shaped, and the liquid waveguide capillary cell) were compared in terms of their sensitivity and response to refractive index changes.
OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A reverse configured flow injection system was developed for the determination of copper in water samples. In this study, a bathocuproine disulfonic acid copper complexing reagent was used. In the presence of a reducing agent (hydroxylamine), the formation of complex was monitored at 484 nm. The determination range extended from 1 to 40 µg L−1, with an applicable determination rate of 40 h−1. The developed method was applied to the determination of copper in water samples (estuarine, river, and drinking water) and showed good accuracy (z-score below 2). The detection limit of 0.7 µg L−1 copper is consistent with the requirement of the target water samples. The developed method was also used for the comparison of different spectrophotometric flow cells. Alternative flow cells (U, Z shaped, and the liquid waveguide capillary cell) were compared in terms of their sensitivity and response to refractive index changes.
Key concepts: Chemistry, Copper, Reagent, Hydroxylamine, Detection limit, Flow injection analysis, Spectrophotometry, Chromatography