1973Archives of OphthalmologyRequires access

Silicone Elastomer Implantation Cyclodialysis

Gerald L. Portney

Open publisher page 15 citations

Abstract

Five eyes with severe secondary angleclosure glaucoma were operated upon using the silicone elastomer (Silastic) implantation cyclodialysis procedure. It was not possible to thereby significantly reduce the intraocular pressure except for one eye, which also underwent a cyclodiathermy. Microscopic examination of this eye and two other eyes revealed an inflammatory reaction surrounding the silicone elastomer that obliterated the connection between the anterior chamber and suprachoroidal space. The silicone elastomer implant cyclodialysis is not recommended for severe secondary angle-closure glaucoma.

About this research paper

What this paper is about

Five eyes with severe secondary angleclosure glaucoma were operated upon using the silicone elastomer (Silastic) implantation cyclodialysis procedure. It was not possible to thereby significantly reduce the intraocular pressure except for one eye, which also underwent a cyclodiathermy. Microscopic examination of this eye and two other eyes revealed an inflammatory reaction surrounding the silicone elastomer that obliterated the connection between the anterior chamber and suprachoroidal space. The silicone elastomer implant cyclodialysis is not recommended for severe secondary angle-closure glaucoma.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Five eyes with severe secondary angleclosure glaucoma were operated upon using the silicone elastomer (Silastic) implantation cyclodialysis procedure. It was not possible to thereby significantly reduce the intraocular pressure except for one eye, which also underwent a cyclodiathermy. Microscopic examination of this eye and two other eyes revealed an inflammatory reaction surrounding the silicone elastomer that obliterated the connection between the anterior chamber and suprachoroidal space. The silicone elastomer implant cyclodialysis is not recommended for severe secondary angle-closure glaucoma.

Key concepts: Silastic, Silicone, Silicone Elastomers, Medicine, Elastomer, Glaucoma, Implant, Intraocular pressure

Related papers

Back to paper searchBrowse research topicsOriginal source
Silicone Elastomer Implantation Cyclodialysis — Research Paper | ScholarLens