Purification of a Flavonoid Sample by Countercurrent Chromatography
Alain Berthod, Karine Talabardon, François De La Poype, Clemens A. J. Erdelmeier
Abstract
Alain Berthod, Karine Talabardon, François De La Poype, Clemens A. J. Erdelmeier
Abstract
A quercitrin rich vegetal flavonoid sample was fractionated using a new hydrodynamic CCC apparatus based on the Ito scheme IV design. The Kromaton CCC apparatus has two spools with a tube coiling allowing work with two different apparatus volumes. The small “analytical” volume was 94 mL and the large “preparative” volume was 1.07 L. The fractionation of the flavonoid sample was done using the two machine volumes. The bi phasic liquid system was a non chlorinated solvent system, butanone/water. UV detection was possible at 330 nm. In one run, 330 mg of the flavonoid sample could be fractionated by the CCC machine in six peaks that were collected in nine fractions. The HPLC and MS analysis of the fractions allowed identification of the main constituents of the sample. Quercitrin, a rhamno-flavonoid, was the major compound making up more than 88% w/w of the studied sample. The three minor identified flavonoids were quercetin, kaempferol, and kaempferol-3-rhamnoglucoside. Six very minor impurities were detected by the HPLC analysis of the fractions, but they were not unambiguously identified.
OpenAlex reports 8 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A quercitrin rich vegetal flavonoid sample was fractionated using a new hydrodynamic CCC apparatus based on the Ito scheme IV design. The Kromaton CCC apparatus has two spools with a tube coiling allowing work with two different apparatus volumes. The small “analytical” volume was 94 mL and the large “preparative” volume was 1.07 L. The fractionation of the flavonoid sample was done using the two machine volumes. The bi phasic liquid system was a non chlorinated solvent system, butanone/water. UV detection was possible at 330 nm. In one run, 330 mg of the flavonoid sample could be fractionated by the CCC machine in six peaks that were collected in nine fractions. The HPLC and MS analysis of the fractions allowed identification of the main constituents of the sample. Quercitrin, a rhamno-flavonoid, was the major compound making up more than 88% w/w of the studied sample. The three minor identified flavonoids were quercetin, kaempferol, and kaempferol-3-rhamnoglucoside. Six very minor impurities were detected by the HPLC analysis of the fractions, but they were not unambiguously identified.
Key concepts: Quercitrin, Chemistry, Chromatography, Kaempferol, Flavonoid, High-performance liquid chromatography, Fractionation, Quercetin