1988Cement Concrete and AggregatesRequires access

Analytical Investigation of the Influence of Air Bubble Size on the Determination of the Air Content of Freshly Mixed Concrete

K C Hover

Open publisher page 11 citations

Abstract

Abstract It has been qualitatively suggested that the pressure method for the determination of air content in freshly mixed concrete can be in error when a portion of the entrained air bubbles becomes relatively incompressible due to the increase in internal bubble pressure which accompanies a reduction in bubble diameter. This has been used to explain the observed discrepancy between air meter readings and the air volume reported by microscopic analysis. This paper reports the results of an analytical investigation of the bubble-size effect, in which it is seen that it is unlikely that a sufficient volume of bubbles with the required diameter are present so as to cause the observed discrepancy. In order to demonstrate a significant influence of bubble size on the accuracy of the air meter, one must resort to values for the surface tension of the bubble film which are unjustified. The characteristics of various meters are discussed.

About this research paper

What this paper is about

Abstract It has been qualitatively suggested that the pressure method for the determination of air content in freshly mixed concrete can be in error when a portion of the entrained air bubbles becomes relatively incompressible due to the increase in internal bubble pressure which accompanies a reduction in bubble diameter. This has been used to explain the observed discrepancy between air meter readings and the air volume reported by microscopic analysis. This paper reports the results of an analytical investigation of the bubble-size effect, in which it is seen that it is unlikely that a sufficient volume of bubbles with the required diameter are present so as to cause the observed discrepancy. In order to demonstrate a significant influence of bubble size on the accuracy of the air meter, one must resort to values for the surface tension of the bubble film which are unjustified. The characteristics of various meters are discussed.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract It has been qualitatively suggested that the pressure method for the determination of air content in freshly mixed concrete can be in error when a portion of the entrained air bubbles becomes relatively incompressible due to the increase in internal bubble pressure which accompanies a reduction in bubble diameter. This has been used to explain the observed discrepancy between air meter readings and the air volume reported by microscopic analysis. This paper reports the results of an analytical investigation of the bubble-size effect, in which it is seen that it is unlikely that a sufficient volume of bubbles with the required diameter are present so as to cause the observed discrepancy. In order to demonstrate a significant influence of bubble size on the accuracy of the air meter, one must resort to values for the surface tension of the bubble film which are unjustified. The characteristics of various meters are discussed.

Key concepts: Bubble, Air bubble, Content (measure theory), Environmental science, Materials science, Composite material, Mechanics, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Analytical Investigation of the Influence of Air Bubble Size on the Determination of the Air Content of Freshly Mixed Concrete — Research Paper | ScholarLens