2013Journal of Environmental ProtectionOpen access

Physico-Chemical and Biological Characteristics of Stagnant Surface Water Bodies (Ponds and Lakes) Used for Drinking and Domestic Purposes in Niger Delta, Nigeria

Akpofure Rim-Rukeh

Open full text 15 citations

Abstract

The surface water quality of some stagnant water bodies (ponds and lakes—Obi Lake, Usede pond, Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake, Abua lake, Ikarama lake, Tenmako lake, and Adiegbe lake) in the Niger Delta area of Nigeria have been investigated experimentally by analysing the physico-chemical and biological characteristics of the surface water samples. Results show: pH (5.10 - 7.40), temperature (26.4°C - 31.0°C), turbidity (7.83 - 27.7NTU), electrical conductivity (13.5 - 34.8 μS/cm), biochemical oxygen demand (BOD) (1.07 - 19.5 mg/l), chemical oxygen demand (COD) (1.90 - 21.5 mg/l), suspended solids (SS) (9.70 - 37.3 mg/l), dissolved oxygen (DO) (2.7 - 8.7 mg/l), total dissolved solids (TDS) (33.8 - 187.0 mg/l), total phosphorus (0.73 - 2.47 mg/l), ammoniacal nitrogen (AN) (0.018 - 4.70 mg/l) and total fecal coliform count (TFCC) (nil - 2175 cfu/ml). Results on the water quality using Malaysian Water Quality Index (WQI) show that Usede pond and Obi Lake belong to Class II with values that are 75.24 and 76.73 respectively. The WQI of Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake and Abua lake are 67.46, 65.64, 65.87, 50.77, and 67.01 respectively and belongs to class III. The WQI of Ikarama lake, Tenmako lake, and Adiegbe lake are 43.38, 37.60, and 41.40, respectively and belongs to class IV and is described as fair.

Open-access reader

About this research paper

What this paper is about

The surface water quality of some stagnant water bodies (ponds and lakes—Obi Lake, Usede pond, Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake, Abua lake, Ikarama lake, Tenmako lake, and Adiegbe lake) in the Niger Delta area of Nigeria have been investigated experimentally by analysing the physico-chemical and biological characteristics of the surface water samples. Results show: pH (5.10 - 7.40), temperature (26.4°C - 31.0°C), turbidity (7.83 - 27.7NTU), electrical conductivity (13.5 - 34.8 μS/cm), biochemical oxygen demand (BOD) (1.07 - 19.5 mg/l), chemical oxygen demand (COD) (1.90 - 21.5 mg/l), suspended solids (SS) (9.70 - 37.3 mg/l), dissolved oxygen (DO) (2.7 - 8.7 mg/l), total dissolved solids (TDS) (33.8 - 187.0 mg/l), total phosphorus (0.73 - 2.47 mg/l), ammoniacal nitrogen (AN) (0.018 - 4.70 mg/l) and total fecal coliform count (TFCC) (nil - 2175 cfu/ml). Results on the water quality using Malaysian Water Quality Index (WQI) show that Usede pond and Obi Lake belong to Class II with values that are 75.24 and 76.73 respectively. The WQI of Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake and Abua lake are 67.46, 65.64, 65.87, 50.77, and 67.01 respectively and belongs to class III. The WQI of Ikarama lake, Tenmako lake, and Adiegbe lake are 43.38, 37.60, and 41.40, respectively and belongs to class IV and is described as fair.

Why it matters

OpenAlex reports 15 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The surface water quality of some stagnant water bodies (ponds and lakes—Obi Lake, Usede pond, Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake, Abua lake, Ikarama lake, Tenmako lake, and Adiegbe lake) in the Niger Delta area of Nigeria have been investigated experimentally by analysing the physico-chemical and biological characteristics of the surface water samples. Results show: pH (5.10 - 7.40), temperature (26.4°C - 31.0°C), turbidity (7.83 - 27.7NTU), electrical conductivity (13.5 - 34.8 μS/cm), biochemical oxygen demand (BOD) (1.07 - 19.5 mg/l), chemical oxygen demand (COD) (1.90 - 21.5 mg/l), suspended solids (SS) (9.70 - 37.3 mg/l), dissolved oxygen (DO) (2.7 - 8.7 mg/l), total dissolved solids (TDS) (33.8 - 187.0 mg/l), total phosphorus (0.73 - 2.47 mg/l), ammoniacal nitrogen (AN) (0.018 - 4.70 mg/l) and total fecal coliform count (TFCC) (nil - 2175 cfu/ml). Results on the water quality using Malaysian Water Quality Index (WQI) show that Usede pond and Obi Lake belong to Class II with values that are 75.24 and 76.73 respectively. The WQI of Oguta lake, Omuku pond, Ugheghe pond, Karabodone lake and Abua lake are 67.46, 65.64, 65.87, 50.77, and 67.01 respectively and belongs to class III. The WQI of Ikarama lake, Tenmako lake, and Adiegbe lake are 43.38, 37.60, and 41.40, respectively and belongs to class IV and is described as fair.

Key concepts: Turbidity, Biochemical oxygen demand, Water quality, Chemical oxygen demand, Total dissolved solids, Niger delta, Hydrology (agriculture), Total suspended solids

Related papers

Back to paper searchBrowse research topicsOriginal source
Physico-Chemical and Biological Characteristics of Stagnant Surface Water Bodies (Ponds and Lakes) Used for Drinking and Domestic Purposes in Niger Delta, Nigeria — Research Paper | ScholarLens