Modified DAT/IAT Process for Removal of Ammonia Nitrogen from Domestic Sewage

Shoubin Zhang, Maoan Du, Liping Qu

Open publisher page 3 citations

Abstract

A biological contact oxidation reactor (BCOR) was set up behind demand aeration tank/intermittent aeration tank (DAT/TAT). The removal effect of ammonia nitrogen (NH3-N) from domestic wastewater in the combined process was investigated. The results show that when the operating periods of IAT are set at two hours for aeration, one hour for sedimentation, one hour for effluent, and HRT of the BCOR is three hours, the combined process is able to remove an average of 81.1% for NH3-N, and the average NH3-N concentration in the effluent is 7.0 mg/L. The effluent quality meets the requirements of the Reuse of Urban Recycling Water-Water Quality Standard for Urban Miscellaneous Water Consumption (GB/T 18920- 2002). The removal efficiency of NH3-N declines along with the increase of influent COD concentration. When the influent COD is 815.3 mg/L, the effluent NH3-N concentration still meets the requirements of GB/T 18920-2002. However, as the influent NH3-N concentration gradually increases, the removal efficiency of NH3-N slightly increases at first and then obviously decreases. The influent NH3-N concentration should be controlled at below 50 mg/L to ensure the effluent NH3-N concentration reach the reuse standard. The appropriate pH range is 7 to 8, and the values outside this range may cause the decrease in the removal efficiency of NH3-N.

About this research paper

What this paper is about

A biological contact oxidation reactor (BCOR) was set up behind demand aeration tank/intermittent aeration tank (DAT/TAT). The removal effect of ammonia nitrogen (NH3-N) from domestic wastewater in the combined process was investigated. The results show that when the operating periods of IAT are set at two hours for aeration, one hour for sedimentation, one hour for effluent, and HRT of the BCOR is three hours, the combined process is able to remove an average of 81.1% for NH3-N, and the average NH3-N concentration in the effluent is 7.0 mg/L. The effluent quality meets the requirements of the Reuse of Urban Recycling Water-Water Quality Standard for Urban Miscellaneous Water Consumption (GB/T 18920- 2002). The removal efficiency of NH3-N declines along with the increase of influent COD concentration. When the influent COD is 815.3 mg/L, the effluent NH3-N concentration still meets the requirements of GB/T 18920-2002. However, as the influent NH3-N concentration gradually increases, the removal efficiency of NH3-N slightly increases at first and then obviously decreases. The influent NH3-N concentration should be controlled at below 50 mg/L to ensure the effluent NH3-N concentration reach the reuse standard. The appropriate pH range is 7 to 8, and the values outside this range may cause the decrease in the removal efficiency of NH3-N.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A biological contact oxidation reactor (BCOR) was set up behind demand aeration tank/intermittent aeration tank (DAT/TAT). The removal effect of ammonia nitrogen (NH3-N) from domestic wastewater in the combined process was investigated. The results show that when the operating periods of IAT are set at two hours for aeration, one hour for sedimentation, one hour for effluent, and HRT of the BCOR is three hours, the combined process is able to remove an average of 81.1% for NH3-N, and the average NH3-N concentration in the effluent is 7.0 mg/L. The effluent quality meets the requirements of the Reuse of Urban Recycling Water-Water Quality Standard for Urban Miscellaneous Water Consumption (GB/T 18920- 2002). The removal efficiency of NH3-N declines along with the increase of influent COD concentration. When the influent COD is 815.3 mg/L, the effluent NH3-N concentration still meets the requirements of GB/T 18920-2002. However, as the influent NH3-N concentration gradually increases, the removal efficiency of NH3-N slightly increases at first and then obviously decreases. The influent NH3-N concentration should be controlled at below 50 mg/L to ensure the effluent NH3-N concentration reach the reuse standard. The appropriate pH range is 7 to 8, and the values outside this range may cause the decrease in the removal efficiency of NH3-N.

Key concepts: Effluent, Aeration, Wastewater, Sewage treatment, Ammonia, Environmental science, Sewage, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Modified DAT/IAT Process for Removal of Ammonia Nitrogen from Domestic Sewage — Research Paper | ScholarLens