1992Foot & AnkleRequires access

A Method for Measuring Foot Pressures Using a High Resolution, Computerized Insole Sensor: The Effect of Heel Wedges on Plantar Pressure Distribution and Center of Force

Nicholas E. Rose, Lawrence A. Feiwell, Andrea Cracchiolo

Open publisher page 117 citations

Abstract

A new, high resolution, pressure-sensitive insole was tested and found to provide reproducible measurements of static and dynamic plantar pressures inside the shoe of normal test subjects under certain conditions. However, calibration between separate sensors was poor and the sensor pads showed significant wear with use. This system was also used to investigate the effect of heel wedges on plantar foot pressure to determine whether this system was sensitive enough to detect the effect of a gross shoe modification on plantar foot pressure. Medial heel wedges decreased plantar pressures under the first and second metatarsals as well as under the first toe, and shifted the center of force laterally in all portions of the foot. Lateral heel wedges decreased pressures under the third, fourth, and fifth metatarsals, increased pressures under the first and second metatarsals, and shifted the center of force medially in all portions of the foot. Our evaluations indicate that it is possible to measure static and dynamic plantar foot pressures within shoes and to study the possible effect of shoe modifications on plantar pressures in controlled gait trials.

About this research paper

What this paper is about

A new, high resolution, pressure-sensitive insole was tested and found to provide reproducible measurements of static and dynamic plantar pressures inside the shoe of normal test subjects under certain conditions. However, calibration between separate sensors was poor and the sensor pads showed significant wear with use. This system was also used to investigate the effect of heel wedges on plantar foot pressure to determine whether this system was sensitive enough to detect the effect of a gross shoe modification on plantar foot pressure. Medial heel wedges decreased plantar pressures under the first and second metatarsals as well as under the first toe, and shifted the center of force laterally in all portions of the foot. Lateral heel wedges decreased pressures under the third, fourth, and fifth metatarsals, increased pressures under the first and second metatarsals, and shifted the center of force medially in all portions of the foot. Our evaluations indicate that it is possible to measure static and dynamic plantar foot pressures within shoes and to study the possible effect of shoe modifications on plantar pressures in controlled gait trials.

Why it matters

OpenAlex reports 117 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A new, high resolution, pressure-sensitive insole was tested and found to provide reproducible measurements of static and dynamic plantar pressures inside the shoe of normal test subjects under certain conditions. However, calibration between separate sensors was poor and the sensor pads showed significant wear with use. This system was also used to investigate the effect of heel wedges on plantar foot pressure to determine whether this system was sensitive enough to detect the effect of a gross shoe modification on plantar foot pressure. Medial heel wedges decreased plantar pressures under the first and second metatarsals as well as under the first toe, and shifted the center of force laterally in all portions of the foot. Lateral heel wedges decreased pressures under the third, fourth, and fifth metatarsals, increased pressures under the first and second metatarsals, and shifted the center of force medially in all portions of the foot. Our evaluations indicate that it is possible to measure static and dynamic plantar foot pressures within shoes and to study the possible effect of shoe modifications on plantar pressures in controlled gait trials.

Key concepts: Plantar pressure, Heel, Foot (prosody), Center of pressure (fluid mechanics), Calibration, Gait, Geology, Pressure measurement

Related papers

Back to paper searchBrowse research topicsOriginal source
A Method for Measuring Foot Pressures Using a High Resolution, Computerized Insole Sensor: The Effect of Heel Wedges on Plantar Pressure Distribution and Center of Force — Research Paper | ScholarLens