2005•Annals of Plastic SurgeryRequires access

End-to-Side Nerve Coaptation

Serhat zbek, M. �zcan, Behzat Noyan, Mustafa Ayberk Kurt, Ser in Tireliolu, Cengiz Bozkurt, Kemal Karaca, G??laydan Filiz

Open publisher page 6 citations

Abstract

In Brief The aim of this experimental study was to evaluate the effects of end-to-side coaptation of the proximal end of a severed nerve to the same intact nerve, in addition to traditional end-to-side coaptation of the distal end, with an aim to use the intact nerve as a nerve conduit in a rat model and to compare the functional and histologic results of this modality to those obtained after nerve grafting and traditional end-to-side nerve coaptation. In group A, a peroneal nerve defect measuring 1 cm was created in the left hind limb, and a nerve graft 1 cm long was used to bridge the defect. In group B, only the distal stump of the peroneal nerve was coapted to the intact tibial nerve. In group C, both ends of the peroneal nerve defect were coapted to the intact tibial nerve in an end-to-side fashion 1.5 cm apart from each other, and in group D, the peroneal nerve defect was left unrepaired. Group E was consisted of nonoperated peroneal nerves that were used to obtain normative data. Although significantly higher myelinated axon densities were observed in groups B and C compared with group A and group E, total number of the myelinated axons was significantly higher only in group C. Peroneal functional index assessments demonstrated that nerve recovery in the peroneal nerve was similar in groups A and C, and both were better than those observed in groups B and D. Collectively, these results suggest that end-to-side coaptation of both ends of a severed nerve to an intact nerve, in case of a nerve defect in this length, may serve as an alternative for nerve grafting. In a rat model a 1-cm peroneal nerve defect was repaired by end-to-side coaptation of (1) the distal stump or (2) both proximal and distal stumps into the intact tibial nerve. Total number of myelinated axons was greater when both stumps were coapted, and walking track analysis demonstrated comparability of this group to nerve grafting.

About this research paper

What this paper is about

In Brief The aim of this experimental study was to evaluate the effects of end-to-side coaptation of the proximal end of a severed nerve to the same intact nerve, in addition to traditional end-to-side coaptation of the distal end, with an aim to use the intact nerve as a nerve conduit in a rat model and to compare the functional and histologic results of this modality to those obtained after nerve grafting and traditional end-to-side nerve coaptation. In group A, a peroneal nerve defect measuring 1 cm was created in the left hind limb, and a nerve graft 1 cm long was used to bridge the defect. In group B, only the distal stump of the peroneal nerve was coapted to the intact tibial nerve. In group C, both ends of the peroneal nerve defect were coapted to the intact tibial nerve in an end-to-side fashion 1.5 cm apart from each other, and in group D, the peroneal nerve defect was left unrepaired. Group E was consisted of nonoperated peroneal nerves that were used to obtain normative data. Although significantly higher myelinated axon densities were observed in groups B and C compared with group A and group E, total number of the myelinated axons was significantly higher only in group C. Peroneal functional index assessments demonstrated that nerve recovery in the peroneal nerve was similar in groups A and C, and both were better than those observed in groups B and D. Collectively, these results suggest that end-to-side coaptation of both ends of a severed nerve to an intact nerve, in case of a nerve defect in this length, may serve as an alternative for nerve grafting. In a rat model a 1-cm peroneal nerve defect was repaired by end-to-side coaptation of (1) the distal stump or (2) both proximal and distal stumps into the intact tibial nerve. Total number of myelinated axons was greater when both stumps were coapted, and walking track analysis demonstrated comparability of this group to nerve grafting.

Why it matters

OpenAlex reports 6 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In Brief The aim of this experimental study was to evaluate the effects of end-to-side coaptation of the proximal end of a severed nerve to the same intact nerve, in addition to traditional end-to-side coaptation of the distal end, with an aim to use the intact nerve as a nerve conduit in a rat model and to compare the functional and histologic results of this modality to those obtained after nerve grafting and traditional end-to-side nerve coaptation. In group A, a peroneal nerve defect measuring 1 cm was created in the left hind limb, and a nerve graft 1 cm long was used to bridge the defect. In group B, only the distal stump of the peroneal nerve was coapted to the intact tibial nerve. In group C, both ends of the peroneal nerve defect were coapted to the intact tibial nerve in an end-to-side fashion 1.5 cm apart from each other, and in group D, the peroneal nerve defect was left unrepaired. Group E was consisted of nonoperated peroneal nerves that were used to obtain normative data. Although significantly higher myelinated axon densities were observed in groups B and C compared with group A and group E, total number of the myelinated axons was significantly higher only in group C. Peroneal functional index assessments demonstrated that nerve recovery in the peroneal nerve was similar in groups A and C, and both were better than those observed in groups B and D. Collectively, these results suggest that end-to-side coaptation of both ends of a severed nerve to an intact nerve, in case of a nerve defect in this length, may serve as an alternative for nerve grafting. In a rat model a 1-cm peroneal nerve defect was repaired by end-to-side coaptation of (1) the distal stump or (2) both proximal and distal stumps into the intact tibial nerve. Total number of myelinated axons was greater when both stumps were coapted, and walking track analysis demonstrated comparability of this group to nerve grafting.

Key concepts: Medicine, Anatomy, Surgery

Related papers

Back to paper searchBrowse research topicsOriginal source
End-to-Side Nerve Coaptation — Research Paper | ScholarLens