2014•Journal of Liquid Chromatography & Related TechnologiesRequires access

QUANTIFICATION OF PANTOPRAZOLE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) METHOD: IN VITRO AND IN VIVO APPLICATIONS

Jaber Emami, Mahboubeh Rezazadeh, Mojtaba Kalani

Open publisher page 14 citations

Abstract

A simple, sensitive, and selective HPLC method with UV detection was developed and validated for quantitation of pantoprazole in enteric coated tablets, dissolution medium, and human plasma following simple liquid–liquid extraction. The separation was achieved on a μ-Bondapak C18 HPLC column using sodium hydrogen phosphate solution (0.01 M)/acetonitrile (60/40 v/v) at pH 7.4 ± 0.1, as the mobile phase at a flow rate of 1.5 mL/min. Omeprazole was used as the internal standard for analysis of plasma samples. The retention time for pantoprazole and omeprazole were 8.4 and 7 min, respectively. Calibration curve was linear in the range of 0.025–5 µg/mL of pantoprazole using human plasma with the average recovery of 85 ± 5%. Within-day and between-day precision and accuracy did not exceed 14.4% and 15.8%, respectively. The HPLC assay was performed isocratically on a reversed-phase column with UV detection. A limit of quantification of 25 ng/mL achieved in our study was approximately twenty times smaller than that of other reported methods. The assay was applied to the analysis of pantoprazole levels in plasma collected from healthy participants entered to the pharmacokinetic study of this drug.

About this research paper

What this paper is about

A simple, sensitive, and selective HPLC method with UV detection was developed and validated for quantitation of pantoprazole in enteric coated tablets, dissolution medium, and human plasma following simple liquid–liquid extraction. The separation was achieved on a μ-Bondapak C18 HPLC column using sodium hydrogen phosphate solution (0.01 M)/acetonitrile (60/40 v/v) at pH 7.4 ± 0.1, as the mobile phase at a flow rate of 1.5 mL/min. Omeprazole was used as the internal standard for analysis of plasma samples. The retention time for pantoprazole and omeprazole were 8.4 and 7 min, respectively. Calibration curve was linear in the range of 0.025–5 µg/mL of pantoprazole using human plasma with the average recovery of 85 ± 5%. Within-day and between-day precision and accuracy did not exceed 14.4% and 15.8%, respectively. The HPLC assay was performed isocratically on a reversed-phase column with UV detection. A limit of quantification of 25 ng/mL achieved in our study was approximately twenty times smaller than that of other reported methods. The assay was applied to the analysis of pantoprazole levels in plasma collected from healthy participants entered to the pharmacokinetic study of this drug.

Why it matters

OpenAlex reports 14 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A simple, sensitive, and selective HPLC method with UV detection was developed and validated for quantitation of pantoprazole in enteric coated tablets, dissolution medium, and human plasma following simple liquid–liquid extraction. The separation was achieved on a μ-Bondapak C18 HPLC column using sodium hydrogen phosphate solution (0.01 M)/acetonitrile (60/40 v/v) at pH 7.4 ± 0.1, as the mobile phase at a flow rate of 1.5 mL/min. Omeprazole was used as the internal standard for analysis of plasma samples. The retention time for pantoprazole and omeprazole were 8.4 and 7 min, respectively. Calibration curve was linear in the range of 0.025–5 µg/mL of pantoprazole using human plasma with the average recovery of 85 ± 5%. Within-day and between-day precision and accuracy did not exceed 14.4% and 15.8%, respectively. The HPLC assay was performed isocratically on a reversed-phase column with UV detection. A limit of quantification of 25 ng/mL achieved in our study was approximately twenty times smaller than that of other reported methods. The assay was applied to the analysis of pantoprazole levels in plasma collected from healthy participants entered to the pharmacokinetic study of this drug.

Key concepts: Chromatography, Pantoprazole, Chemistry, High-performance liquid chromatography, Calibration curve, Detection limit, Coefficient of variation, Quantitative analysis (chemistry)

Related papers

Back to paper searchBrowse research topicsOriginal source
QUANTIFICATION OF PANTOPRAZOLE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY (HPLC) METHOD: IN VITRO AND IN VIVO APPLICATIONS — Research Paper | ScholarLens