2005Optometry and Vision ScienceRequires access

Comparisons of the Handheld Autorefractor, Table‐Mounted Autorefractor, and Subjective Refraction in Singapore Adults

Mohamed Farook, Jayant Venkatramani, Gus Gazzard, Angela Cheng, Donald Tan, Seang‐Mei Saw

Open publisher page 49 citations

Abstract

PURPOSE: The purpose of this article was to compare the Retinomax with the table-mounted autorefractor and subjective refraction in Singapore adults. METHODS: Adults (n = 100) attending a tertiary eye hospital clinic were examined by an optometrist. First, subjective refraction testing was performed using a trial lens set, followed by handheld autorefractor tests using the Nikon Retinomax and the table-mounted autorefractor (Topcon RM8000B). Spherical equivalent and vector components of astigmatism were analyzed: J0 (Cartesian astigmatism) and J45 (oblique astigmatism). RESULTS: The Retinomax autorefractor readings (mean = -4.69 D) were more minus compared with the table-mounted autorefractor (mean = -4.05 D) and subjective refraction (mean = -3.90 D). There were significant differences in J0 and J45 for comparisons between subjective refraction and Retinomax autorefraction, and table-mounted autorefraction and Retinomax autorefraction. CONCLUSION: The Retinomax autorefractor measures were more minus compared with the table-mounted autorefractor and subjective refraction. The Retinomax autorefractor is not recommended for research purposes, unless in remote inaccessible areas where a portable instrument is necessary and cycloplegia is not possible.

About this research paper

What this paper is about

PURPOSE: The purpose of this article was to compare the Retinomax with the table-mounted autorefractor and subjective refraction in Singapore adults. METHODS: Adults (n = 100) attending a tertiary eye hospital clinic were examined by an optometrist. First, subjective refraction testing was performed using a trial lens set, followed by handheld autorefractor tests using the Nikon Retinomax and the table-mounted autorefractor (Topcon RM8000B). Spherical equivalent and vector components of astigmatism were analyzed: J0 (Cartesian astigmatism) and J45 (oblique astigmatism). RESULTS: The Retinomax autorefractor readings (mean = -4.69 D) were more minus compared with the table-mounted autorefractor (mean = -4.05 D) and subjective refraction (mean = -3.90 D). There were significant differences in J0 and J45 for comparisons between subjective refraction and Retinomax autorefraction, and table-mounted autorefraction and Retinomax autorefraction. CONCLUSION: The Retinomax autorefractor measures were more minus compared with the table-mounted autorefractor and subjective refraction. The Retinomax autorefractor is not recommended for research purposes, unless in remote inaccessible areas where a portable instrument is necessary and cycloplegia is not possible.

Why it matters

OpenAlex reports 49 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: The purpose of this article was to compare the Retinomax with the table-mounted autorefractor and subjective refraction in Singapore adults. METHODS: Adults (n = 100) attending a tertiary eye hospital clinic were examined by an optometrist. First, subjective refraction testing was performed using a trial lens set, followed by handheld autorefractor tests using the Nikon Retinomax and the table-mounted autorefractor (Topcon RM8000B). Spherical equivalent and vector components of astigmatism were analyzed: J0 (Cartesian astigmatism) and J45 (oblique astigmatism). RESULTS: The Retinomax autorefractor readings (mean = -4.69 D) were more minus compared with the table-mounted autorefractor (mean = -4.05 D) and subjective refraction (mean = -3.90 D). There were significant differences in J0 and J45 for comparisons between subjective refraction and Retinomax autorefraction, and table-mounted autorefraction and Retinomax autorefraction. CONCLUSION: The Retinomax autorefractor measures were more minus compared with the table-mounted autorefractor and subjective refraction. The Retinomax autorefractor is not recommended for research purposes, unless in remote inaccessible areas where a portable instrument is necessary and cycloplegia is not possible.

Key concepts: Autorefractor, Astigmatism, Subjective refraction, Cycloplegia, Optometry, Refraction, Table (database), Refractive error

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparisons of the Handheld Autorefractor, Table‐Mounted Autorefractor, and Subjective Refraction in Singapore Adults — Research Paper | ScholarLens