Comparisons of the Handheld Autorefractor, Table‐Mounted Autorefractor, and Subjective Refraction in Singapore Adults
Mohamed Farook, Jayant Venkatramani, Gus Gazzard, Angela Cheng, Donald Tan, Seang‐Mei Saw
Abstract
Mohamed Farook, Jayant Venkatramani, Gus Gazzard, Angela Cheng, Donald Tan, Seang‐Mei Saw
Abstract
PURPOSE: The purpose of this article was to compare the Retinomax with the table-mounted autorefractor and subjective refraction in Singapore adults. METHODS: Adults (n = 100) attending a tertiary eye hospital clinic were examined by an optometrist. First, subjective refraction testing was performed using a trial lens set, followed by handheld autorefractor tests using the Nikon Retinomax and the table-mounted autorefractor (Topcon RM8000B). Spherical equivalent and vector components of astigmatism were analyzed: J0 (Cartesian astigmatism) and J45 (oblique astigmatism). RESULTS: The Retinomax autorefractor readings (mean = -4.69 D) were more minus compared with the table-mounted autorefractor (mean = -4.05 D) and subjective refraction (mean = -3.90 D). There were significant differences in J0 and J45 for comparisons between subjective refraction and Retinomax autorefraction, and table-mounted autorefraction and Retinomax autorefraction. CONCLUSION: The Retinomax autorefractor measures were more minus compared with the table-mounted autorefractor and subjective refraction. The Retinomax autorefractor is not recommended for research purposes, unless in remote inaccessible areas where a portable instrument is necessary and cycloplegia is not possible.
OpenAlex reports 49 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
PURPOSE: The purpose of this article was to compare the Retinomax with the table-mounted autorefractor and subjective refraction in Singapore adults. METHODS: Adults (n = 100) attending a tertiary eye hospital clinic were examined by an optometrist. First, subjective refraction testing was performed using a trial lens set, followed by handheld autorefractor tests using the Nikon Retinomax and the table-mounted autorefractor (Topcon RM8000B). Spherical equivalent and vector components of astigmatism were analyzed: J0 (Cartesian astigmatism) and J45 (oblique astigmatism). RESULTS: The Retinomax autorefractor readings (mean = -4.69 D) were more minus compared with the table-mounted autorefractor (mean = -4.05 D) and subjective refraction (mean = -3.90 D). There were significant differences in J0 and J45 for comparisons between subjective refraction and Retinomax autorefraction, and table-mounted autorefraction and Retinomax autorefraction. CONCLUSION: The Retinomax autorefractor measures were more minus compared with the table-mounted autorefractor and subjective refraction. The Retinomax autorefractor is not recommended for research purposes, unless in remote inaccessible areas where a portable instrument is necessary and cycloplegia is not possible.
Key concepts: Autorefractor, Astigmatism, Subjective refraction, Cycloplegia, Optometry, Refraction, Table (database), Refractive error