1980American Industrial Hygiene Association JournalRequires access

Respirator protection factors: part II — protection factors of supplied-air respirators

A Hack, O.D. Bradley, Andrés Miniguano–Trujillo

Open publisher page 18 citations

Abstract

Protection Factors provided by 25 NIOSH approved supplied-air respirators were determined while the devices were worn by a panel of test subjects anthropometrically selected to represent adult facial sizes. Polydispersed DOP aerosol was used for respirator fit tests on continuous flow, demand, and pressure-demand respirators. Based on facepiece leakage measurements it appears that demand-type respirators should neither be used nor approved. The highest level of protection was provided by pressure-demand devices.

About this research paper

What this paper is about

Protection Factors provided by 25 NIOSH approved supplied-air respirators were determined while the devices were worn by a panel of test subjects anthropometrically selected to represent adult facial sizes. Polydispersed DOP aerosol was used for respirator fit tests on continuous flow, demand, and pressure-demand respirators. Based on facepiece leakage measurements it appears that demand-type respirators should neither be used nor approved. The highest level of protection was provided by pressure-demand devices.

Why it matters

OpenAlex reports 18 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Protection Factors provided by 25 NIOSH approved supplied-air respirators were determined while the devices were worn by a panel of test subjects anthropometrically selected to represent adult facial sizes. Polydispersed DOP aerosol was used for respirator fit tests on continuous flow, demand, and pressure-demand respirators. Based on facepiece leakage measurements it appears that demand-type respirators should neither be used nor approved. The highest level of protection was provided by pressure-demand devices.

Key concepts: Respirator, Environmental science, Automotive engineering, Engineering, Materials science, Composite material

Related papers

Back to paper searchBrowse research topicsOriginal source
Respirator protection factors: part II — protection factors of supplied-air respirators — Research Paper | ScholarLens