The high efficiency of well-type detector is one of its important advantages, when it is used to determine the low level activity of radiation in many different fields. In the present work the full-energy peak efficiency of 3" × 3" NaI(Tl) well-type scintillation detector was calculated. The calculations were based on the efficiency transfer principle and a new straightforward analytical definition to compute the effective solid angle between a point source and the detector surfaces Moreover, the effective solid angle ratio subtended by the well-type detector and a point source located out the detector cavity at various distances was calculated, the attenuation of the photon by the source-detector system [detectorendcap,deadlayer and holder material] was considered and determined. This method is easily useful in setting up the efficiency calibration curve for well-type detectors when the source is outside. The computed efficiency values are found to be in a good agreement with the experimental data obtained in the case of radiating γ -ray standard point sources.

Open-access reader

About this research paper

What this paper is about

The high efficiency of well-type detector is one of its important advantages, when it is used to determine the low level activity of radiation in many different fields. In the present work the full-energy peak efficiency of 3" × 3" NaI(Tl) well-type scintillation detector was calculated. The calculations were based on the efficiency transfer principle and a new straightforward analytical definition to compute the effective solid angle between a point source and the detector surfaces Moreover, the effective solid angle ratio subtended by the well-type detector and a point source located out the detector cavity at various distances was calculated, the attenuation of the photon by the source-detector system [detectorendcap,deadlayer and holder material] was considered and determined. This method is easily useful in setting up the efficiency calibration curve for well-type detectors when the source is outside. The computed efficiency values are found to be in a good agreement with the experimental data obtained in the case of radiating γ -ray standard point sources.

Why it matters

OpenAlex reports 40 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The high efficiency of well-type detector is one of its important advantages, when it is used to determine the low level activity of radiation in many different fields. In the present work the full-energy peak efficiency of 3" × 3" NaI(Tl) well-type scintillation detector was calculated. The calculations were based on the efficiency transfer principle and a new straightforward analytical definition to compute the effective solid angle between a point source and the detector surfaces Moreover, the effective solid angle ratio subtended by the well-type detector and a point source located out the detector cavity at various distances was calculated, the attenuation of the photon by the source-detector system [detectorendcap,deadlayer and holder material] was considered and determined. This method is easily useful in setting up the efficiency calibration curve for well-type detectors when the source is outside. The computed efficiency values are found to be in a good agreement with the experimental data obtained in the case of radiating γ -ray standard point sources.

Key concepts: Detector, Solid angle, Calibration, Physics, Optics, Point source, Radiation, Photon