2008Veterinary Radiology & UltrasoundRequires access

EFFECT OF CONTRAST MEDIA FORMULATION ON COMPUTED TOMOGRAPHY ANGIOGRAPHIC CONTRAST ENHANCEMENT

Miori KISHIMOTO, Kazutaka YAMADA, RYO TSUNEDA, Junichiro SHIMIZU, Toshiroh Iwasaki, Yoh-Ichi MIYAKE

Open publisher page 16 citations

Abstract

The characteristics of contrast media formulation (mgI/ml, osmolarity, and viscosity) are generally not considered important in computed tomography (CT) angiography in animals. The purpose of this study was to assess the contrast effect in CT angiography as a function of contrast media formulation, with a constant iodine dose. The contrast effects of three contrast media with different iodine concentrations were compared by administering identical iodine dosages (mgI/kg). The contrast effects of the three contrast media differed, and the area under the time-attenuation curve of iohexol 350 mgI/ml, which had the highest iodine concentration, was the lowest. It was hypothesized that the contrast effect of a contrast medium decreases with higher iodine concentration because of the high amount of residual iodine present in the circulatory system from the injection site to the portion immediately before the great vessels. In addition, the influence of osmotic dilution on contrast media with high osmolarity was also considered. In conclusion, the contrast effect varies with different contrast media formulations, even when the same iodine dosage is administered.

About this research paper

What this paper is about

The characteristics of contrast media formulation (mgI/ml, osmolarity, and viscosity) are generally not considered important in computed tomography (CT) angiography in animals. The purpose of this study was to assess the contrast effect in CT angiography as a function of contrast media formulation, with a constant iodine dose. The contrast effects of three contrast media with different iodine concentrations were compared by administering identical iodine dosages (mgI/kg). The contrast effects of the three contrast media differed, and the area under the time-attenuation curve of iohexol 350 mgI/ml, which had the highest iodine concentration, was the lowest. It was hypothesized that the contrast effect of a contrast medium decreases with higher iodine concentration because of the high amount of residual iodine present in the circulatory system from the injection site to the portion immediately before the great vessels. In addition, the influence of osmotic dilution on contrast media with high osmolarity was also considered. In conclusion, the contrast effect varies with different contrast media formulations, even when the same iodine dosage is administered.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The characteristics of contrast media formulation (mgI/ml, osmolarity, and viscosity) are generally not considered important in computed tomography (CT) angiography in animals. The purpose of this study was to assess the contrast effect in CT angiography as a function of contrast media formulation, with a constant iodine dose. The contrast effects of three contrast media with different iodine concentrations were compared by administering identical iodine dosages (mgI/kg). The contrast effects of the three contrast media differed, and the area under the time-attenuation curve of iohexol 350 mgI/ml, which had the highest iodine concentration, was the lowest. It was hypothesized that the contrast effect of a contrast medium decreases with higher iodine concentration because of the high amount of residual iodine present in the circulatory system from the injection site to the portion immediately before the great vessels. In addition, the influence of osmotic dilution on contrast media with high osmolarity was also considered. In conclusion, the contrast effect varies with different contrast media formulations, even when the same iodine dosage is administered.

Key concepts: Iohexol, Contrast (vision), Iodine, Medicine, Contrast medium, Iodinated contrast media, Iodinated contrast, Nuclear medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
EFFECT OF CONTRAST MEDIA FORMULATION ON COMPUTED TOMOGRAPHY ANGIOGRAPHIC CONTRAST ENHANCEMENT — Research Paper | ScholarLens