2012IEEE Transactions on Power ElectronicsRequires access

Perturbation On-Time (POT) Technique in Power Factor Correction (PFC) Controller for Low Total Harmonic Distortion and High Power Factor

Jen-Chieh Tsai, Chi-Lin Chen, Yi‐Ting Chen, Chia-Lung Ni, Chun‐Yen Chen, Ke‐Horng Chen

Open publisher page 36 citations

Abstract

The proposed perturbation on-time technique suppresses total harmonic distortion (THD) and, thus, improves the power factor in the power factor correction (PFC) controller. Besides, the adaptive control of the minimum off time by the proposed inhibit time control can improve efficiency even at low ac input voltage. Therefore, highly integrated PFC converter fabricated in the TSMC 800-V ultrahigh voltage process can achieve low THD of 6%, high PF of 99%, and high efficiency of 95% at the output power of 90 W.

About this research paper

What this paper is about

The proposed perturbation on-time technique suppresses total harmonic distortion (THD) and, thus, improves the power factor in the power factor correction (PFC) controller. Besides, the adaptive control of the minimum off time by the proposed inhibit time control can improve efficiency even at low ac input voltage. Therefore, highly integrated PFC converter fabricated in the TSMC 800-V ultrahigh voltage process can achieve low THD of 6%, high PF of 99%, and high efficiency of 95% at the output power of 90 W.

Why it matters

OpenAlex reports 36 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The proposed perturbation on-time technique suppresses total harmonic distortion (THD) and, thus, improves the power factor in the power factor correction (PFC) controller. Besides, the adaptive control of the minimum off time by the proposed inhibit time control can improve efficiency even at low ac input voltage. Therefore, highly integrated PFC converter fabricated in the TSMC 800-V ultrahigh voltage process can achieve low THD of 6%, high PF of 99%, and high efficiency of 95% at the output power of 90 W.

Key concepts: Total harmonic distortion, Power factor, Control theory (sociology), Voltage, AC power, Perturbation (astronomy), Harmonic analysis, Engineering

Related papers

Back to paper searchBrowse research topicsOriginal source
Perturbation On-Time (POT) Technique in Power Factor Correction (PFC) Controller for Low Total Harmonic Distortion and High Power Factor — Research Paper | ScholarLens