2005Journal of Endovascular TherapyRequires access

Effect of Stent Oversizing on In-Stent Stenosis and Lumen Size in Normal Porcine Veins

Carlos Zamora, Koji Sugimoto, Masato Yamaguchi, Kazuro Sugimura

Open publisher page 7 citations

Abstract

PURPOSE: To present an in vivo evaluation of the effects of stent oversizing on in-stent stenosis and on actual lumen size in normal veins. METHODS: Twelve self-expanding stents were implanted in the common iliac veins of 6 minipigs, which were divided in 2 groups for follow-up at 1 and 3 months, respectively. Oversizing ranged from 119.5% to 216% of the original vessel diameter. Intravascular ultrasound (IVUS) was used to measure vessel areas at the stent edges and midpoint. In-stent stenosis and decrease in actual lumen size were evaluated with IVUS immediately after implantation and during follow-up. RESULTS: There was a very strong positive linear regression between stent oversizing and in-stent stenosis in the 1-month model (r=0.947, p=0.004), in the 3-month model (r=0.931, p=0.007), and in the sum of these 2 groups (r=0.83, p<0.001). Regarding the change in actual lumen size, we found a strong negative linear regression with stent oversizing in the 1-month (r=-0.754, p=0.083) and the 3-month (r=-0.562, p=0.246) groups, but these did not attain statistical significance. However, a strong correlation between stent oversizing and a decrease in lumen size in all samples proved to be statistically significant (r=0.619, p=0.032). CONCLUSIONS: Stent oversizing was strongly correlated with increased in-stent stenosis and decreased actual lumen size at follow-up in normal non-stenotic porcine veins.

About this research paper

What this paper is about

PURPOSE: To present an in vivo evaluation of the effects of stent oversizing on in-stent stenosis and on actual lumen size in normal veins. METHODS: Twelve self-expanding stents were implanted in the common iliac veins of 6 minipigs, which were divided in 2 groups for follow-up at 1 and 3 months, respectively. Oversizing ranged from 119.5% to 216% of the original vessel diameter. Intravascular ultrasound (IVUS) was used to measure vessel areas at the stent edges and midpoint. In-stent stenosis and decrease in actual lumen size were evaluated with IVUS immediately after implantation and during follow-up. RESULTS: There was a very strong positive linear regression between stent oversizing and in-stent stenosis in the 1-month model (r=0.947, p=0.004), in the 3-month model (r=0.931, p=0.007), and in the sum of these 2 groups (r=0.83, p<0.001). Regarding the change in actual lumen size, we found a strong negative linear regression with stent oversizing in the 1-month (r=-0.754, p=0.083) and the 3-month (r=-0.562, p=0.246) groups, but these did not attain statistical significance. However, a strong correlation between stent oversizing and a decrease in lumen size in all samples proved to be statistically significant (r=0.619, p=0.032). CONCLUSIONS: Stent oversizing was strongly correlated with increased in-stent stenosis and decreased actual lumen size at follow-up in normal non-stenotic porcine veins.

Why it matters

OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To present an in vivo evaluation of the effects of stent oversizing on in-stent stenosis and on actual lumen size in normal veins. METHODS: Twelve self-expanding stents were implanted in the common iliac veins of 6 minipigs, which were divided in 2 groups for follow-up at 1 and 3 months, respectively. Oversizing ranged from 119.5% to 216% of the original vessel diameter. Intravascular ultrasound (IVUS) was used to measure vessel areas at the stent edges and midpoint. In-stent stenosis and decrease in actual lumen size were evaluated with IVUS immediately after implantation and during follow-up. RESULTS: There was a very strong positive linear regression between stent oversizing and in-stent stenosis in the 1-month model (r=0.947, p=0.004), in the 3-month model (r=0.931, p=0.007), and in the sum of these 2 groups (r=0.83, p<0.001). Regarding the change in actual lumen size, we found a strong negative linear regression with stent oversizing in the 1-month (r=-0.754, p=0.083) and the 3-month (r=-0.562, p=0.246) groups, but these did not attain statistical significance. However, a strong correlation between stent oversizing and a decrease in lumen size in all samples proved to be statistically significant (r=0.619, p=0.032). CONCLUSIONS: Stent oversizing was strongly correlated with increased in-stent stenosis and decreased actual lumen size at follow-up in normal non-stenotic porcine veins.

Key concepts: Medicine, Stent, Stenosis, Lumen (anatomy), Radiology, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Effect of Stent Oversizing on In-Stent Stenosis and Lumen Size in Normal Porcine Veins — Research Paper | ScholarLens