2003Thrombosis and HaemostasisRequires access

Thrombin generation in severe haemophilia A and B: the endogenous thrombin potential in platelet-rich plasma

Thomas Siegemund, A. Siegemund, Ute Scholz, Lothar Engelmann, Sirak Petros

Open publisher page 86 citations

Abstract

Thrombin generation was investigated in platelet-rich plasma (PRP) from 11 healthy controls, 17 patients with severe haemophilia A and 7 patients with severe haemophilia B. Mean endogenous thrombin potential (ETP) in arbitrary fluorescence units (FU) was 226.9 +/- 44.6, 186.4 +/- 22.5, 154.2 +/- 41.3 in controls, haemophilia A and B, respectively, all at a platelet count of 200 x 10(9)/l (p = 0.004 for controls vs. haemophilia A, p = 0.003 for controls vs. haemophilia B, no significant difference between haemophilia A and B). The contribution of FVIII to thrombin generation in haemophilia A was 1.31 +/- 0.16 FU/% of FVIII:C activity, while for FIX in haemophilia B this was 0.80 +/- 0.21 FU/% of FIX activity. There was an almost linear relationship between increasing platelet count and thrombin generation up to a mean platelet count of 100 x 10(9)/l. Further increase in platelet count has only a marginal influence on thrombin generation. Platelets increase ETP in haemophilia A by 0.184 +/- 0.022 FU/10(9) platelets/l and in haemophilia B by 0.319 +/- 0.085 FU/10(9) platelets/l, and this was significantly different between the two groups (p = 0.0002). This influence of plate-lets diminishes with increasing concentration of either FVIII or FIX. In conclusion, there is a difference in thrombin generation between haemophilia A and B, and this may be attributed to the role of platelets in the assembly of the tenase complex on their surface.

About this research paper

What this paper is about

Thrombin generation was investigated in platelet-rich plasma (PRP) from 11 healthy controls, 17 patients with severe haemophilia A and 7 patients with severe haemophilia B. Mean endogenous thrombin potential (ETP) in arbitrary fluorescence units (FU) was 226.9 +/- 44.6, 186.4 +/- 22.5, 154.2 +/- 41.3 in controls, haemophilia A and B, respectively, all at a platelet count of 200 x 10(9)/l (p = 0.004 for controls vs. haemophilia A, p = 0.003 for controls vs. haemophilia B, no significant difference between haemophilia A and B). The contribution of FVIII to thrombin generation in haemophilia A was 1.31 +/- 0.16 FU/% of FVIII:C activity, while for FIX in haemophilia B this was 0.80 +/- 0.21 FU/% of FIX activity. There was an almost linear relationship between increasing platelet count and thrombin generation up to a mean platelet count of 100 x 10(9)/l. Further increase in platelet count has only a marginal influence on thrombin generation. Platelets increase ETP in haemophilia A by 0.184 +/- 0.022 FU/10(9) platelets/l and in haemophilia B by 0.319 +/- 0.085 FU/10(9) platelets/l, and this was significantly different between the two groups (p = 0.0002). This influence of plate-lets diminishes with increasing concentration of either FVIII or FIX. In conclusion, there is a difference in thrombin generation between haemophilia A and B, and this may be attributed to the role of platelets in the assembly of the tenase complex on their surface.

Why it matters

OpenAlex reports 86 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Thrombin generation was investigated in platelet-rich plasma (PRP) from 11 healthy controls, 17 patients with severe haemophilia A and 7 patients with severe haemophilia B. Mean endogenous thrombin potential (ETP) in arbitrary fluorescence units (FU) was 226.9 +/- 44.6, 186.4 +/- 22.5, 154.2 +/- 41.3 in controls, haemophilia A and B, respectively, all at a platelet count of 200 x 10(9)/l (p = 0.004 for controls vs. haemophilia A, p = 0.003 for controls vs. haemophilia B, no significant difference between haemophilia A and B). The contribution of FVIII to thrombin generation in haemophilia A was 1.31 +/- 0.16 FU/% of FVIII:C activity, while for FIX in haemophilia B this was 0.80 +/- 0.21 FU/% of FIX activity. There was an almost linear relationship between increasing platelet count and thrombin generation up to a mean platelet count of 100 x 10(9)/l. Further increase in platelet count has only a marginal influence on thrombin generation. Platelets increase ETP in haemophilia A by 0.184 +/- 0.022 FU/10(9) platelets/l and in haemophilia B by 0.319 +/- 0.085 FU/10(9) platelets/l, and this was significantly different between the two groups (p = 0.0002). This influence of plate-lets diminishes with increasing concentration of either FVIII or FIX. In conclusion, there is a difference in thrombin generation between haemophilia A and B, and this may be attributed to the role of platelets in the assembly of the tenase complex on their surface.

Key concepts: Haemophilia, Haemophilia A, Platelet, Thrombin, Thrombin generation, Medicine, Haemophilia B, Immunology

Related papers

Back to paper searchBrowse research topicsOriginal source
Thrombin generation in severe haemophilia A and B: the endogenous thrombin potential in platelet-rich plasma — Research Paper | ScholarLens