1977•Physics in Medicine and BiologyRequires access

The re-estimation of absorbed doses of less than 1 rad measured with lithium fluoride thermoluminescent dosemeters

E W Mason, A.F. McKinlay, D. Saunders

Open publisher page 11 citations

Abstract

The technique of ultraviolet light bleaching for the re-estimation of the absorbed dose of radiation received by lithium fluoride thermoluminescence dosemeters has been extended to the extruded ribbon and PTFE disc form of dosemeter. The threshold of detection for the re-estimation of absorbed dose was found to be 1-1 rad for the PTFE disc dosemeters and 2-8 rad for the extruded ribbon dosemeters. A further study of this technique has revealed that by raising the temperature of the dosemeter during bleaching the threshold for re-estimated absorbed doses may be substantially reduced. The optimum temperature was found to be 80 degrees C and the practical threshold for the re-estimation of absorbed dose using a PTFE disc dosemeter was determined as 750 mrad.

About this research paper

What this paper is about

The technique of ultraviolet light bleaching for the re-estimation of the absorbed dose of radiation received by lithium fluoride thermoluminescence dosemeters has been extended to the extruded ribbon and PTFE disc form of dosemeter. The threshold of detection for the re-estimation of absorbed dose was found to be 1-1 rad for the PTFE disc dosemeters and 2-8 rad for the extruded ribbon dosemeters. A further study of this technique has revealed that by raising the temperature of the dosemeter during bleaching the threshold for re-estimated absorbed doses may be substantially reduced. The optimum temperature was found to be 80 degrees C and the practical threshold for the re-estimation of absorbed dose using a PTFE disc dosemeter was determined as 750 mrad.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The technique of ultraviolet light bleaching for the re-estimation of the absorbed dose of radiation received by lithium fluoride thermoluminescence dosemeters has been extended to the extruded ribbon and PTFE disc form of dosemeter. The threshold of detection for the re-estimation of absorbed dose was found to be 1-1 rad for the PTFE disc dosemeters and 2-8 rad for the extruded ribbon dosemeters. A further study of this technique has revealed that by raising the temperature of the dosemeter during bleaching the threshold for re-estimated absorbed doses may be substantially reduced. The optimum temperature was found to be 80 degrees C and the practical threshold for the re-estimation of absorbed dose using a PTFE disc dosemeter was determined as 750 mrad.

Key concepts: Thermoluminescence, Lithium fluoride, Thermoluminescent dosimeter, Absorbed dose, Lithium borate, Materials science, Lithium (medication), Thermoluminescent Dosimetry

Related papers

Back to paper searchBrowse research topicsOriginal source
The re-estimation of absorbed doses of less than 1 rad measured with lithium fluoride thermoluminescent dosemeters — Research Paper | ScholarLens