2003•The Journal of the Acoustical Society of AmericaRequires access

Blind deconvolution applied to acoustical systems identification with supporting experimental results

Michael J. Roan, Mark R. Gramann, Josh G. Erling, Leon H. Sibul

Open publisher page 20 citations

Abstract

Many acoustical applications require the analysis of a signal that is corrupted by an unknown filtering function. Examples arise in the areas of noise or vibration control, room acoustics, structural vibration analysis, and speech processing. Here, the observed signal can be modeled as the convolution of the desired signal with an unknown system impulse response. Blind deconvolution refers to the process of learning the inverse of this unknown impulse response and applying it to the observed signal to remove the filtering effects. Unlike classical deconvolution, which requires prior knowledge of the impulse response, blind deconvolution requires only reasonable prior estimates of the input signal's statistics. The significant contribution of this work lies in experimental verification of a blind deconvolution algorithm in the context of acoustical system identification. Previous experimental work concerning blind deconvolution in acoustics has been minimal, as previous literature concerning blind deconvolution uses computer simulated data. This paper examines experiments involving three classical acoustic systems: driven pipe, driven pipe with open side branch, and driven pipe with Helmholtz resonator side branch. Experimental results confirm that the deconvolution algorithm learns these systems' inverse impulse responses, and that application of these learned inverses removes the effects of the filters.

About this research paper

What this paper is about

Many acoustical applications require the analysis of a signal that is corrupted by an unknown filtering function. Examples arise in the areas of noise or vibration control, room acoustics, structural vibration analysis, and speech processing. Here, the observed signal can be modeled as the convolution of the desired signal with an unknown system impulse response. Blind deconvolution refers to the process of learning the inverse of this unknown impulse response and applying it to the observed signal to remove the filtering effects. Unlike classical deconvolution, which requires prior knowledge of the impulse response, blind deconvolution requires only reasonable prior estimates of the input signal's statistics. The significant contribution of this work lies in experimental verification of a blind deconvolution algorithm in the context of acoustical system identification. Previous experimental work concerning blind deconvolution in acoustics has been minimal, as previous literature concerning blind deconvolution uses computer simulated data. This paper examines experiments involving three classical acoustic systems: driven pipe, driven pipe with open side branch, and driven pipe with Helmholtz resonator side branch. Experimental results confirm that the deconvolution algorithm learns these systems' inverse impulse responses, and that application of these learned inverses removes the effects of the filters.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Many acoustical applications require the analysis of a signal that is corrupted by an unknown filtering function. Examples arise in the areas of noise or vibration control, room acoustics, structural vibration analysis, and speech processing. Here, the observed signal can be modeled as the convolution of the desired signal with an unknown system impulse response. Blind deconvolution refers to the process of learning the inverse of this unknown impulse response and applying it to the observed signal to remove the filtering effects. Unlike classical deconvolution, which requires prior knowledge of the impulse response, blind deconvolution requires only reasonable prior estimates of the input signal's statistics. The significant contribution of this work lies in experimental verification of a blind deconvolution algorithm in the context of acoustical system identification. Previous experimental work concerning blind deconvolution in acoustics has been minimal, as previous literature concerning blind deconvolution uses computer simulated data. This paper examines experiments involving three classical acoustic systems: driven pipe, driven pipe with open side branch, and driven pipe with Helmholtz resonator side branch. Experimental results confirm that the deconvolution algorithm learns these systems' inverse impulse responses, and that application of these learned inverses removes the effects of the filters.

Key concepts: Blind deconvolution, Deconvolution, Impulse response, Acoustics, SIGNAL (programming language), Computer science, Inverse filter, Signal processing

Related papers

Back to paper searchBrowse research topicsOriginal source
Blind deconvolution applied to acoustical systems identification with supporting experimental results — Research Paper | ScholarLens