2008Blood Coagulation & FibrinolysisRequires access

Rotational thromboelastography for monitoring of fibrinogen concentrate therapy in fibrinogen deficiency

Uwe Kalina, Hans-Arnold Stöhr, H. Bickhard, Sigurd Knaub, Simona Maria Siboni, Pier Mannuccio Mannucci, Flora Peyvandi

Open publisher page 77 citations

Abstract

To characterize a functional assay for circulating fibrinogen based on rotational thrombelastography. Maximum clot firmness was determined by rotational thrombelastography in normal human plasma pool, fibrinogen-deficient plasma pool, normal whole blood, and individual plasma samples from 17 patients with fibrinogen deficiency. Plasma samples spiked with varying concentrations of exogenous fibrinogen were also measured. Results were compared with enzyme-linked immunosorbent assay and Clauss assay. The impact of sample freezing and filtration and use of cytochalasin D were also investigated. Over the tested range of 0-3 mg/ml added exogenous fibrinogen, the maximum clot firmness standard curve for determination of fibrinogen in plasma pools (n = 7) was linear (r2 = 0.97). Maximum clot firmness was highly linearly correlated both with Clauss assay (r2 = 0.93) and enzyme-linked immunosorbent assay (r2 = 0.95). In unspiked plasma samples from individual patients with fibrinogen deficiency, fibrinogen was undetectable by rotational thromboelastography. By all evaluated methods, the response to spiking with fibrinogen in such samples coincided closely in patients with afibrinogenemia and hypofibrinogenemia. In dysfibrinogenemia, smaller Clauss assay responses to spiking were observed, whereas the enzyme-linked immunosorbent assay response was variable. Maximum clot firmness was the only evaluated method of fibrinogen assessment to yield consistent results across all categories of fibrinogen deficiency. These in-vitro results suggest the potential clinical utility of rotational thromboelastography as a versatile method for monitoring the response to fibrinogen concentrate among patients with fibrinogen deficiency. Clinical investigations using rotational thromboelastography after in-vivo fibrinogen administration to patients with congenital fibrinogen deficiency are warranted.

About this research paper

What this paper is about

To characterize a functional assay for circulating fibrinogen based on rotational thrombelastography. Maximum clot firmness was determined by rotational thrombelastography in normal human plasma pool, fibrinogen-deficient plasma pool, normal whole blood, and individual plasma samples from 17 patients with fibrinogen deficiency. Plasma samples spiked with varying concentrations of exogenous fibrinogen were also measured. Results were compared with enzyme-linked immunosorbent assay and Clauss assay. The impact of sample freezing and filtration and use of cytochalasin D were also investigated. Over the tested range of 0-3 mg/ml added exogenous fibrinogen, the maximum clot firmness standard curve for determination of fibrinogen in plasma pools (n = 7) was linear (r2 = 0.97). Maximum clot firmness was highly linearly correlated both with Clauss assay (r2 = 0.93) and enzyme-linked immunosorbent assay (r2 = 0.95). In unspiked plasma samples from individual patients with fibrinogen deficiency, fibrinogen was undetectable by rotational thromboelastography. By all evaluated methods, the response to spiking with fibrinogen in such samples coincided closely in patients with afibrinogenemia and hypofibrinogenemia. In dysfibrinogenemia, smaller Clauss assay responses to spiking were observed, whereas the enzyme-linked immunosorbent assay response was variable. Maximum clot firmness was the only evaluated method of fibrinogen assessment to yield consistent results across all categories of fibrinogen deficiency. These in-vitro results suggest the potential clinical utility of rotational thromboelastography as a versatile method for monitoring the response to fibrinogen concentrate among patients with fibrinogen deficiency. Clinical investigations using rotational thromboelastography after in-vivo fibrinogen administration to patients with congenital fibrinogen deficiency are warranted.

Why it matters

OpenAlex reports 77 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To characterize a functional assay for circulating fibrinogen based on rotational thrombelastography. Maximum clot firmness was determined by rotational thrombelastography in normal human plasma pool, fibrinogen-deficient plasma pool, normal whole blood, and individual plasma samples from 17 patients with fibrinogen deficiency. Plasma samples spiked with varying concentrations of exogenous fibrinogen were also measured. Results were compared with enzyme-linked immunosorbent assay and Clauss assay. The impact of sample freezing and filtration and use of cytochalasin D were also investigated. Over the tested range of 0-3 mg/ml added exogenous fibrinogen, the maximum clot firmness standard curve for determination of fibrinogen in plasma pools (n = 7) was linear (r2 = 0.97). Maximum clot firmness was highly linearly correlated both with Clauss assay (r2 = 0.93) and enzyme-linked immunosorbent assay (r2 = 0.95). In unspiked plasma samples from individual patients with fibrinogen deficiency, fibrinogen was undetectable by rotational thromboelastography. By all evaluated methods, the response to spiking with fibrinogen in such samples coincided closely in patients with afibrinogenemia and hypofibrinogenemia. In dysfibrinogenemia, smaller Clauss assay responses to spiking were observed, whereas the enzyme-linked immunosorbent assay response was variable. Maximum clot firmness was the only evaluated method of fibrinogen assessment to yield consistent results across all categories of fibrinogen deficiency. These in-vitro results suggest the potential clinical utility of rotational thromboelastography as a versatile method for monitoring the response to fibrinogen concentrate among patients with fibrinogen deficiency. Clinical investigations using rotational thromboelastography after in-vivo fibrinogen administration to patients with congenital fibrinogen deficiency are warranted.

Key concepts: Thromboelastography, Fibrinogen, Hypofibrinogenemia, Afibrinogenemia, Thrombelastography, Thromboelastometry, Chemistry, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Rotational thromboelastography for monitoring of fibrinogen concentrate therapy in fibrinogen deficiency — Research Paper | ScholarLens