1997Applied OpticsRequires access

Diffractive lenses for chromatic confocal imaging

Sarah L. Dobson, Pang-Chen Sun, Yeshayahu Fainman

Open publisher page 100 citations

Abstract

A diffractive zone plate provides a highly linear wavelength-to-depth coding, allowing for nonmechanical depth scanning in a confocal microscope. This chromatic confocal microscope, constructed with 40x and 60x objectives, achieves axial position changes of 55 and 25 mum, respectively, for a wavelength tuning range of 100 nm. The corresponding longitudinal point-spread functions are measured and shown to possess full-width half-maximums of 2.52 and 2.23 mum, respectively. Two-dimensional profiles of a two-phase-level grating and a four-phase-level diffractive structure are given. The performance of the chromatic confocal microscope is consistent with that of the conventional confocal operation of the microscope.

About this research paper

What this paper is about

A diffractive zone plate provides a highly linear wavelength-to-depth coding, allowing for nonmechanical depth scanning in a confocal microscope. This chromatic confocal microscope, constructed with 40x and 60x objectives, achieves axial position changes of 55 and 25 mum, respectively, for a wavelength tuning range of 100 nm. The corresponding longitudinal point-spread functions are measured and shown to possess full-width half-maximums of 2.52 and 2.23 mum, respectively. Two-dimensional profiles of a two-phase-level grating and a four-phase-level diffractive structure are given. The performance of the chromatic confocal microscope is consistent with that of the conventional confocal operation of the microscope.

Why it matters

OpenAlex reports 100 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A diffractive zone plate provides a highly linear wavelength-to-depth coding, allowing for nonmechanical depth scanning in a confocal microscope. This chromatic confocal microscope, constructed with 40x and 60x objectives, achieves axial position changes of 55 and 25 mum, respectively, for a wavelength tuning range of 100 nm. The corresponding longitudinal point-spread functions are measured and shown to possess full-width half-maximums of 2.52 and 2.23 mum, respectively. Two-dimensional profiles of a two-phase-level grating and a four-phase-level diffractive structure are given. The performance of the chromatic confocal microscope is consistent with that of the conventional confocal operation of the microscope.

Key concepts: Confocal, Optics, Microscope, Confocal microscopy, Chromatic scale, Materials science, Chromatic aberration, 4Pi microscope

Related papers

Back to paper searchBrowse research topicsOriginal source
Diffractive lenses for chromatic confocal imaging — Research Paper | ScholarLens