Problems in the measurement of functional residual capacity

Simon J. Broughton, Karl Peter Sylvester, Chloe M.L. Page, Gerrard Francis Rafferty, Anthony David Milner, Anne Greenough

Open publisher page 13 citations

Abstract

Accurate assessment of lung volume in infancy is important to determine the impact of disease and the efficacy of therapies. A new generation of infant plethysmographs with lower apparatus deadspace has been produced, but gives lower volume results than those from older traditional plethysmographs. We hypothesized that the new plethysmographs might have greater sensitivity to the adiabatic effect and hence they, rather than the traditional plethysmographs, produced erroneous results. Our aim was to assess the influence of the adiabatic effect on the results of a contemporary plethysmograph, an older traditional plethysmograph and a helium gas dilution system using a lung model. Altering the amount of copper wool within the lung model allowed the influence of the adiabatic effect on the plethysmographic results to be assessed. The measured compared to the actual volumes were significantly lower for the contemporary plethysmograph compared to the traditional plethysmograph (p < 0.001) and to the helium gas dilution system (p < 0.001). Under optimal testing conditions the contemporary plethysmograph under-recorded by 11-13%, whereas the other two systems gave similar results to the actual volumes. As the effect of the adiabatic effect was increased, the discrepancy between the results of the contemporary and the traditional plethysmographs increased. We conclude, the contemporary plethysmograph is more sensitive to adiabatic effects and hence under-records.

About this research paper

What this paper is about

Accurate assessment of lung volume in infancy is important to determine the impact of disease and the efficacy of therapies. A new generation of infant plethysmographs with lower apparatus deadspace has been produced, but gives lower volume results than those from older traditional plethysmographs. We hypothesized that the new plethysmographs might have greater sensitivity to the adiabatic effect and hence they, rather than the traditional plethysmographs, produced erroneous results. Our aim was to assess the influence of the adiabatic effect on the results of a contemporary plethysmograph, an older traditional plethysmograph and a helium gas dilution system using a lung model. Altering the amount of copper wool within the lung model allowed the influence of the adiabatic effect on the plethysmographic results to be assessed. The measured compared to the actual volumes were significantly lower for the contemporary plethysmograph compared to the traditional plethysmograph (p < 0.001) and to the helium gas dilution system (p < 0.001). Under optimal testing conditions the contemporary plethysmograph under-recorded by 11-13%, whereas the other two systems gave similar results to the actual volumes. As the effect of the adiabatic effect was increased, the discrepancy between the results of the contemporary and the traditional plethysmographs increased. We conclude, the contemporary plethysmograph is more sensitive to adiabatic effects and hence under-records.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Accurate assessment of lung volume in infancy is important to determine the impact of disease and the efficacy of therapies. A new generation of infant plethysmographs with lower apparatus deadspace has been produced, but gives lower volume results than those from older traditional plethysmographs. We hypothesized that the new plethysmographs might have greater sensitivity to the adiabatic effect and hence they, rather than the traditional plethysmographs, produced erroneous results. Our aim was to assess the influence of the adiabatic effect on the results of a contemporary plethysmograph, an older traditional plethysmograph and a helium gas dilution system using a lung model. Altering the amount of copper wool within the lung model allowed the influence of the adiabatic effect on the plethysmographic results to be assessed. The measured compared to the actual volumes were significantly lower for the contemporary plethysmograph compared to the traditional plethysmograph (p < 0.001) and to the helium gas dilution system (p < 0.001). Under optimal testing conditions the contemporary plethysmograph under-recorded by 11-13%, whereas the other two systems gave similar results to the actual volumes. As the effect of the adiabatic effect was increased, the discrepancy between the results of the contemporary and the traditional plethysmographs increased. We conclude, the contemporary plethysmograph is more sensitive to adiabatic effects and hence under-records.

Key concepts: Plethysmograph, Adiabatic process, Dilution, Lung volumes, Functional residual capacity, Residual, Medicine, Sensitivity (control systems)