2011•Japanese Journal of Radiological TechnologyOpen access

Assessment of Cross-sectional Area and Diameter of Carotid Artery Using Time-of-flight MR Angiography and CT Angiography

Eriko Yasuda, Tosiaki Miyati

Open full text 10 citations

Abstract

PURPOSE: In carotid artery stenosis, precisely assessing the vessel cross-sectional area and diameter is important because this result determines the treatment strategy for patients. The purpose of our study was to evaluate the vessel sizes of normal and stenotic carotid arteries using time-of-flight magnetic resonance angiography (TOF-MRA) and X-ray CT angiography (CTA). METHOD AND MATERIALS: The TOF-MRA and the CTA data were obtained using 3D TOF-MRA on a 1.5-T MR scanner (1.0 mm slice thickness) and dynamic contrast-enhanced multi-detector row CT (0.5 mm slice thickness). In thirty-three normal patients (20 men, 13 women, mean age of 66.9±9.0 years) and eighteen patients with carotid artery stenosis (12 men, 6 women, mean age of 74.4±6.4 years), we measured the vessel cross-sectional areas and the diameters of the internal and common carotid arteries (ICAs and CCAs) using TOF-MRA and CTA and a vessel-analytic program of the workstation. RESULTS: The mean cross-sectional areas and diameters of normal ICAs and CCAs determined using TOF-MRA were significantly smaller than those determined using CTA. The percentages of area and diameter stenoses found using TOF-MRA were 7.7 and 14.3% higher than those found using CTA. In six cases in the stenotic group, the stenotic artery showed no signal using TOF-MRA, but the CTA depicted it. CONCLUSION: In both normal and stenotic carotid arteries, TOF-MRA underestimates vessel size more than CTA does.

Open-access reader

About this research paper

What this paper is about

PURPOSE: In carotid artery stenosis, precisely assessing the vessel cross-sectional area and diameter is important because this result determines the treatment strategy for patients. The purpose of our study was to evaluate the vessel sizes of normal and stenotic carotid arteries using time-of-flight magnetic resonance angiography (TOF-MRA) and X-ray CT angiography (CTA). METHOD AND MATERIALS: The TOF-MRA and the CTA data were obtained using 3D TOF-MRA on a 1.5-T MR scanner (1.0 mm slice thickness) and dynamic contrast-enhanced multi-detector row CT (0.5 mm slice thickness). In thirty-three normal patients (20 men, 13 women, mean age of 66.9±9.0 years) and eighteen patients with carotid artery stenosis (12 men, 6 women, mean age of 74.4±6.4 years), we measured the vessel cross-sectional areas and the diameters of the internal and common carotid arteries (ICAs and CCAs) using TOF-MRA and CTA and a vessel-analytic program of the workstation. RESULTS: The mean cross-sectional areas and diameters of normal ICAs and CCAs determined using TOF-MRA were significantly smaller than those determined using CTA. The percentages of area and diameter stenoses found using TOF-MRA were 7.7 and 14.3% higher than those found using CTA. In six cases in the stenotic group, the stenotic artery showed no signal using TOF-MRA, but the CTA depicted it. CONCLUSION: In both normal and stenotic carotid arteries, TOF-MRA underestimates vessel size more than CTA does.

Why it matters

OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: In carotid artery stenosis, precisely assessing the vessel cross-sectional area and diameter is important because this result determines the treatment strategy for patients. The purpose of our study was to evaluate the vessel sizes of normal and stenotic carotid arteries using time-of-flight magnetic resonance angiography (TOF-MRA) and X-ray CT angiography (CTA). METHOD AND MATERIALS: The TOF-MRA and the CTA data were obtained using 3D TOF-MRA on a 1.5-T MR scanner (1.0 mm slice thickness) and dynamic contrast-enhanced multi-detector row CT (0.5 mm slice thickness). In thirty-three normal patients (20 men, 13 women, mean age of 66.9±9.0 years) and eighteen patients with carotid artery stenosis (12 men, 6 women, mean age of 74.4±6.4 years), we measured the vessel cross-sectional areas and the diameters of the internal and common carotid arteries (ICAs and CCAs) using TOF-MRA and CTA and a vessel-analytic program of the workstation. RESULTS: The mean cross-sectional areas and diameters of normal ICAs and CCAs determined using TOF-MRA were significantly smaller than those determined using CTA. The percentages of area and diameter stenoses found using TOF-MRA were 7.7 and 14.3% higher than those found using CTA. In six cases in the stenotic group, the stenotic artery showed no signal using TOF-MRA, but the CTA depicted it. CONCLUSION: In both normal and stenotic carotid arteries, TOF-MRA underestimates vessel size more than CTA does.

Key concepts: Medicine, Angiography, Carotid arteries, Radiology, Nuclear medicine, Cardiology

Related papers

Back to paper searchBrowse research topicsOriginal source
Assessment of Cross-sectional Area and Diameter of Carotid Artery Using Time-of-flight MR Angiography and CT Angiography — Research Paper | ScholarLens