2011•ElectrophoresisRequires access

A multi‐functional electrochemical sensing system using microfluidic technology for the detection of urea and creatinine

Chao-June Huang, Jiun‐Lin Lin, P.H. Chen, Mei‐Jywan Syu, Gwo‐Bin Lee

Open publisher page 32 citations

Abstract

This study presents a new microfluidic system capable of precise measurements of two important biomarkers, urea and creatinine, automatically. In clinical applications, high levels of these two biomarkers are early indicators of nephropathy or renal failure and should be monitored on a regular basis. The microfluidic system is composed of a microfluidic chip, a control circuit system, a compressed air source and several electromagnetic valves to form a handheld system. The microfluidic chip is fabricated by using micro-electromechanical systems and microfluidic techniques comprising electrochemical sensor arrays and polydimethylsiloxane-based microfluidic structures such as micropumps/micromixers, normally closed valves and microchannels. The microfluidic system performs a variety of critical processes including sample pretreatment, mixing, transportation and detection on a single chip. The experimental results show that the entire procedure takes approximately 40 min, which is much faster than the traditional method (more than 6 h). Furthermore, the total sample volume consumed in each operation is only 0.1 mL, which is significantly less than that required in a large system (5 mL). The developed automatic microfluidic system may provide a powerful platform for further clinical applications.

About this research paper

What this paper is about

This study presents a new microfluidic system capable of precise measurements of two important biomarkers, urea and creatinine, automatically. In clinical applications, high levels of these two biomarkers are early indicators of nephropathy or renal failure and should be monitored on a regular basis. The microfluidic system is composed of a microfluidic chip, a control circuit system, a compressed air source and several electromagnetic valves to form a handheld system. The microfluidic chip is fabricated by using micro-electromechanical systems and microfluidic techniques comprising electrochemical sensor arrays and polydimethylsiloxane-based microfluidic structures such as micropumps/micromixers, normally closed valves and microchannels. The microfluidic system performs a variety of critical processes including sample pretreatment, mixing, transportation and detection on a single chip. The experimental results show that the entire procedure takes approximately 40 min, which is much faster than the traditional method (more than 6 h). Furthermore, the total sample volume consumed in each operation is only 0.1 mL, which is significantly less than that required in a large system (5 mL). The developed automatic microfluidic system may provide a powerful platform for further clinical applications.

Why it matters

OpenAlex reports 32 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

This study presents a new microfluidic system capable of precise measurements of two important biomarkers, urea and creatinine, automatically. In clinical applications, high levels of these two biomarkers are early indicators of nephropathy or renal failure and should be monitored on a regular basis. The microfluidic system is composed of a microfluidic chip, a control circuit system, a compressed air source and several electromagnetic valves to form a handheld system. The microfluidic chip is fabricated by using micro-electromechanical systems and microfluidic techniques comprising electrochemical sensor arrays and polydimethylsiloxane-based microfluidic structures such as micropumps/micromixers, normally closed valves and microchannels. The microfluidic system performs a variety of critical processes including sample pretreatment, mixing, transportation and detection on a single chip. The experimental results show that the entire procedure takes approximately 40 min, which is much faster than the traditional method (more than 6 h). Furthermore, the total sample volume consumed in each operation is only 0.1 mL, which is significantly less than that required in a large system (5 mL). The developed automatic microfluidic system may provide a powerful platform for further clinical applications.

Key concepts: Microfluidics, Polydimethylsiloxane, Microfluidic chip, Materials science, Nanotechnology, Chip, Mixing (physics), Lab-on-a-chip

Related papers

Back to paper searchBrowse research topicsOriginal source
A multi‐functional electrochemical sensing system using microfluidic technology for the detection of urea and creatinine — Research Paper | ScholarLens