1984•Scandinavian AudiologyRequires access

A Clinical Comparison Between a Laboratory and a Commercial Impedance Audiometer

K. Karlsson, Björn Hagerman

Open publisher page 3 citations

Abstract

Impedance audiometry is a useful tool in the diagnosis of retrocochlear lesions, provided that adequate normal values regarding the stapedius reflex thresholds and decay are used. The normal values in Sweden (and elsewhere) have been obtained with a laboratory impedance audiometer that is not in common use. We have compared a commercial impedance audiometer, the Grason-Stadler 1723, with this laboratory model to determine whether the normal values are valid. We found that the Grason-Stadler 1723 audiometer gives reliable stapedius reflex thresholds, but at 2-4 dB higher levels. The reflex decay curves, however, are unsatisfactory. Possible explanations for the results are discussed. We have also proposed a modification of the recorder of the commercial audiometer. The study demonstrates that normal values cannot be transferred freely between different equipments.

About this research paper

What this paper is about

Impedance audiometry is a useful tool in the diagnosis of retrocochlear lesions, provided that adequate normal values regarding the stapedius reflex thresholds and decay are used. The normal values in Sweden (and elsewhere) have been obtained with a laboratory impedance audiometer that is not in common use. We have compared a commercial impedance audiometer, the Grason-Stadler 1723, with this laboratory model to determine whether the normal values are valid. We found that the Grason-Stadler 1723 audiometer gives reliable stapedius reflex thresholds, but at 2-4 dB higher levels. The reflex decay curves, however, are unsatisfactory. Possible explanations for the results are discussed. We have also proposed a modification of the recorder of the commercial audiometer. The study demonstrates that normal values cannot be transferred freely between different equipments.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Impedance audiometry is a useful tool in the diagnosis of retrocochlear lesions, provided that adequate normal values regarding the stapedius reflex thresholds and decay are used. The normal values in Sweden (and elsewhere) have been obtained with a laboratory impedance audiometer that is not in common use. We have compared a commercial impedance audiometer, the Grason-Stadler 1723, with this laboratory model to determine whether the normal values are valid. We found that the Grason-Stadler 1723 audiometer gives reliable stapedius reflex thresholds, but at 2-4 dB higher levels. The reflex decay curves, however, are unsatisfactory. Possible explanations for the results are discussed. We have also proposed a modification of the recorder of the commercial audiometer. The study demonstrates that normal values cannot be transferred freely between different equipments.

Key concepts: Audiometer, Audiology, Audiometry, Acoustic reflex, Electrical impedance, Reflex, Acoustics, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
A Clinical Comparison Between a Laboratory and a Commercial Impedance Audiometer — Research Paper | ScholarLens