2004•Biological and Pharmaceutical BulletinOpen access

Monoclonal Antibodies and Sandwich ELISA for Quantitation of HM-1 Killer Toxin

Tadazumi Komiyama, Qingzhu Zhang, Masahiko Miyamoto, Dakshnamurthy Selvakumar, Yasuhiro Furuichi

Open full text 5 citations

Abstract

To establish a method for quantitative analysis of HM-1 killer toxin (HM-1), two purified mouse monoclonal antibodies, 1F1 and 4A2, and rabbit polyclonal antiserum against HM-1 were prepared. Both monoclonal antibodies were classified as IgG1(kappa) subtype, and did not neutralize the killing activity of HM-1. By SPOTs analysis, the epitope of 1F1 was found in the sequence of CDPNTG with a corresponding sequence of 11-16 from N-terminal amino acid residues of HM-1, but the epitope of 4A2 was not determined. Using 4A2 and polyclonal antiserum, the sandwich enzyme-linked immunosorbent assay (ELISA) was applied to establish the quantitative determination of HM-1. The concentration of HM-1 was determined successfully at the range of 2.5-100 ng/ml. But in the case of 1F1, the method was not established. Genes were constructed to apply the system to the measurement of the secreted concentrations of mutant HM-1, and it was evident that the production of mutant toxins varied among HM-1 mutant genes. The findings of this study are unique in determinimg the epitope of monoclonal antibody against HM-1, and in quantifying the HM-1 using the spot analysis and sandwich ELISA methods.

Open-access reader

About this research paper

What this paper is about

To establish a method for quantitative analysis of HM-1 killer toxin (HM-1), two purified mouse monoclonal antibodies, 1F1 and 4A2, and rabbit polyclonal antiserum against HM-1 were prepared. Both monoclonal antibodies were classified as IgG1(kappa) subtype, and did not neutralize the killing activity of HM-1. By SPOTs analysis, the epitope of 1F1 was found in the sequence of CDPNTG with a corresponding sequence of 11-16 from N-terminal amino acid residues of HM-1, but the epitope of 4A2 was not determined. Using 4A2 and polyclonal antiserum, the sandwich enzyme-linked immunosorbent assay (ELISA) was applied to establish the quantitative determination of HM-1. The concentration of HM-1 was determined successfully at the range of 2.5-100 ng/ml. But in the case of 1F1, the method was not established. Genes were constructed to apply the system to the measurement of the secreted concentrations of mutant HM-1, and it was evident that the production of mutant toxins varied among HM-1 mutant genes. The findings of this study are unique in determinimg the epitope of monoclonal antibody against HM-1, and in quantifying the HM-1 using the spot analysis and sandwich ELISA methods.

Why it matters

OpenAlex reports 5 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

To establish a method for quantitative analysis of HM-1 killer toxin (HM-1), two purified mouse monoclonal antibodies, 1F1 and 4A2, and rabbit polyclonal antiserum against HM-1 were prepared. Both monoclonal antibodies were classified as IgG1(kappa) subtype, and did not neutralize the killing activity of HM-1. By SPOTs analysis, the epitope of 1F1 was found in the sequence of CDPNTG with a corresponding sequence of 11-16 from N-terminal amino acid residues of HM-1, but the epitope of 4A2 was not determined. Using 4A2 and polyclonal antiserum, the sandwich enzyme-linked immunosorbent assay (ELISA) was applied to establish the quantitative determination of HM-1. The concentration of HM-1 was determined successfully at the range of 2.5-100 ng/ml. But in the case of 1F1, the method was not established. Genes were constructed to apply the system to the measurement of the secreted concentrations of mutant HM-1, and it was evident that the production of mutant toxins varied among HM-1 mutant genes. The findings of this study are unique in determinimg the epitope of monoclonal antibody against HM-1, and in quantifying the HM-1 using the spot analysis and sandwich ELISA methods.

Key concepts: Polyclonal antibodies, Epitope, Monoclonal antibody, Antiserum, Molecular biology, Toxin, Monoclonal, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Monoclonal Antibodies and Sandwich ELISA for Quantitation of HM-1 Killer Toxin — Research Paper | ScholarLens