2000•Acta Ophthalmologica ScandinavicaOpen access

Regional differences in optic disc and retinal circulation

Bernard Schwartz, Alon Harris, Takenori Takamoto, Larry Kagemann, David T. Evans, Hak Sung Chung

Open full text 16 citations

Abstract

PURPOSE: To determine regional differences in the circulation of the optic disc, the peripapillary choroid and the retinal vessels using the techniques of computerized image analysis and fluorescein angiography. METHODS: Ten young normal subjects were studied. Fluorescein angiography was performed with a scanning laser ophthalmoscope. The rate of filling of fluorescein or slope was measured in the four quadrants of the optic disc, the peripapillary choroid and the major retinal arteries and veins. A total of 125 points was measured from each image of the fluorescein angiograms for a total of 20 to 30 images. Retinal vessel width was measured using computerized image analysis. RESULTS: Comparison of the rates of filling of fluorescein or slopes showed significant differences from zero among the four quadrants of the optic disc (p= 0.01 to <0.02), of the peripapillary choroid (p=0.01 to <0.05) and among the major retinal arteries (p=0.01 to <0.02) and retinal veins (p=0.02 to <0.05). No significant differences were noted between the quadrants for retinal arterial width with the retinal veins only showing a significant difference between the inferior nasal and inferior temporal vein (p=0.02 to <0.05). CONCLUSION: Evaluation of the circulation of the optic disc, retina, and peripapillary choroid should take into account regional differences among these structures.

Open-access reader

About this research paper

What this paper is about

PURPOSE: To determine regional differences in the circulation of the optic disc, the peripapillary choroid and the retinal vessels using the techniques of computerized image analysis and fluorescein angiography. METHODS: Ten young normal subjects were studied. Fluorescein angiography was performed with a scanning laser ophthalmoscope. The rate of filling of fluorescein or slope was measured in the four quadrants of the optic disc, the peripapillary choroid and the major retinal arteries and veins. A total of 125 points was measured from each image of the fluorescein angiograms for a total of 20 to 30 images. Retinal vessel width was measured using computerized image analysis. RESULTS: Comparison of the rates of filling of fluorescein or slopes showed significant differences from zero among the four quadrants of the optic disc (p= 0.01 to <0.02), of the peripapillary choroid (p=0.01 to <0.05) and among the major retinal arteries (p=0.01 to <0.02) and retinal veins (p=0.02 to <0.05). No significant differences were noted between the quadrants for retinal arterial width with the retinal veins only showing a significant difference between the inferior nasal and inferior temporal vein (p=0.02 to <0.05). CONCLUSION: Evaluation of the circulation of the optic disc, retina, and peripapillary choroid should take into account regional differences among these structures.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

PURPOSE: To determine regional differences in the circulation of the optic disc, the peripapillary choroid and the retinal vessels using the techniques of computerized image analysis and fluorescein angiography. METHODS: Ten young normal subjects were studied. Fluorescein angiography was performed with a scanning laser ophthalmoscope. The rate of filling of fluorescein or slope was measured in the four quadrants of the optic disc, the peripapillary choroid and the major retinal arteries and veins. A total of 125 points was measured from each image of the fluorescein angiograms for a total of 20 to 30 images. Retinal vessel width was measured using computerized image analysis. RESULTS: Comparison of the rates of filling of fluorescein or slopes showed significant differences from zero among the four quadrants of the optic disc (p= 0.01 to <0.02), of the peripapillary choroid (p=0.01 to <0.05) and among the major retinal arteries (p=0.01 to <0.02) and retinal veins (p=0.02 to <0.05). No significant differences were noted between the quadrants for retinal arterial width with the retinal veins only showing a significant difference between the inferior nasal and inferior temporal vein (p=0.02 to <0.05). CONCLUSION: Evaluation of the circulation of the optic disc, retina, and peripapillary choroid should take into account regional differences among these structures.

Key concepts: Medicine, Retinal, Choroid, Ophthalmology, Optic disc, Fluorescein angiography, Central retinal vein, Retina

Related papers

Back to paper searchBrowse research topicsOriginal source
Regional differences in optic disc and retinal circulation — Research Paper | ScholarLens