2000•Medical PhysicsRequires access

Simultaneous iterative reconstruction for emission and attenuation images in positron emission tomography

Gerhard Glatting, M. Wuchenauer, S. N. Reske

Open publisher page 23 citations

Abstract

The quality of the attenuation correction strongly influences the outcome of the reconstructed emission scan in positron emission tomography. Usually the attenuation correction factors are calculated from the transmission and blank scan and thereafter applied during the reconstruction on the emission data. However, this is not an optimal treatment of the available data, because the emission data themselves contain additional information about attenuation: The optimal treatment must use this information for the determination of the attenuation correction factors. Therefore, our purpose is to investigate a simultaneous emission and attenuation image reconstruction using a maximum likelihood estimator, which takes the attenuation information in the emission data into account. The total maximum likelihood function for emission and transmission is used to derive a one-dimensional Newton-like algorithm for the calculation of the emission and attenuation image. Log-likelihood convergence, mean differences, and the mean of squared differences for the emission image and the attenuation correction factors of a mathematical thorax phantom were determined and compared. As a result we obtain images improved with respect to log likelihood in all cases and with respect to our figures of merit in most cases. We conclude that the simultaneous reconstruction can improve the performance of image reconstruction.

About this research paper

What this paper is about

The quality of the attenuation correction strongly influences the outcome of the reconstructed emission scan in positron emission tomography. Usually the attenuation correction factors are calculated from the transmission and blank scan and thereafter applied during the reconstruction on the emission data. However, this is not an optimal treatment of the available data, because the emission data themselves contain additional information about attenuation: The optimal treatment must use this information for the determination of the attenuation correction factors. Therefore, our purpose is to investigate a simultaneous emission and attenuation image reconstruction using a maximum likelihood estimator, which takes the attenuation information in the emission data into account. The total maximum likelihood function for emission and transmission is used to derive a one-dimensional Newton-like algorithm for the calculation of the emission and attenuation image. Log-likelihood convergence, mean differences, and the mean of squared differences for the emission image and the attenuation correction factors of a mathematical thorax phantom were determined and compared. As a result we obtain images improved with respect to log likelihood in all cases and with respect to our figures of merit in most cases. We conclude that the simultaneous reconstruction can improve the performance of image reconstruction.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The quality of the attenuation correction strongly influences the outcome of the reconstructed emission scan in positron emission tomography. Usually the attenuation correction factors are calculated from the transmission and blank scan and thereafter applied during the reconstruction on the emission data. However, this is not an optimal treatment of the available data, because the emission data themselves contain additional information about attenuation: The optimal treatment must use this information for the determination of the attenuation correction factors. Therefore, our purpose is to investigate a simultaneous emission and attenuation image reconstruction using a maximum likelihood estimator, which takes the attenuation information in the emission data into account. The total maximum likelihood function for emission and transmission is used to derive a one-dimensional Newton-like algorithm for the calculation of the emission and attenuation image. Log-likelihood convergence, mean differences, and the mean of squared differences for the emission image and the attenuation correction factors of a mathematical thorax phantom were determined and compared. As a result we obtain images improved with respect to log likelihood in all cases and with respect to our figures of merit in most cases. We conclude that the simultaneous reconstruction can improve the performance of image reconstruction.

Key concepts: Attenuation, Correction for attenuation, Iterative reconstruction, Imaging phantom, Positron emission tomography, Estimator, Image quality, Emission computed tomography

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous iterative reconstruction for emission and attenuation images in positron emission tomography — Research Paper | ScholarLens