2009Indian Journal of Pharmaceutical SciencesOpen access

Simultaneous HPLC determination of butenafine hydrochloride and betamethasone in a cream formulation

Rajesh Ankam, K. Mukkanti, S Durgaprasad, Mansoor A. Khan

Open full text 16 citations

Abstract

A fast, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of butenafine hydrochloride and betamethasone in cream formulation. The determination was carried out on licrocart licrosphere RP-select B (250x4.6 mm, 5 mu) column in isocratic mode, the mobile phase consisting of 50 mM ammonium acetate buffer and acetonitrile in the ratio of 60:40, adjusted to pH 4.5 +/- 0.1 with glacial acetic acid. The flow rate was 2.0 ml/min and eluent was monitored at 254 nm. The retention times of butenafine hydrochloride and betamethasone were 4.70 min and 7.76 min, respectively, and the resolution factor was greater than 4.0. Linearity of butenafine hydrochloride and betamethasone were in the range of 100-300 mug/ml and 5-15 mug/ml, respectively. The proposed method is also found to be precise and robust for the simultaneous determination of butenafine hydrochloride and betamethasone in cream formulation.

About this research paper

What this paper is about

A fast, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of butenafine hydrochloride and betamethasone in cream formulation. The determination was carried out on licrocart licrosphere RP-select B (250x4.6 mm, 5 mu) column in isocratic mode, the mobile phase consisting of 50 mM ammonium acetate buffer and acetonitrile in the ratio of 60:40, adjusted to pH 4.5 +/- 0.1 with glacial acetic acid. The flow rate was 2.0 ml/min and eluent was monitored at 254 nm. The retention times of butenafine hydrochloride and betamethasone were 4.70 min and 7.76 min, respectively, and the resolution factor was greater than 4.0. Linearity of butenafine hydrochloride and betamethasone were in the range of 100-300 mug/ml and 5-15 mug/ml, respectively. The proposed method is also found to be precise and robust for the simultaneous determination of butenafine hydrochloride and betamethasone in cream formulation.

Why it matters

OpenAlex reports 16 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fast, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of butenafine hydrochloride and betamethasone in cream formulation. The determination was carried out on licrocart licrosphere RP-select B (250x4.6 mm, 5 mu) column in isocratic mode, the mobile phase consisting of 50 mM ammonium acetate buffer and acetonitrile in the ratio of 60:40, adjusted to pH 4.5 +/- 0.1 with glacial acetic acid. The flow rate was 2.0 ml/min and eluent was monitored at 254 nm. The retention times of butenafine hydrochloride and betamethasone were 4.70 min and 7.76 min, respectively, and the resolution factor was greater than 4.0. Linearity of butenafine hydrochloride and betamethasone were in the range of 100-300 mug/ml and 5-15 mug/ml, respectively. The proposed method is also found to be precise and robust for the simultaneous determination of butenafine hydrochloride and betamethasone in cream formulation.

Key concepts: Chromatography, Chemistry, Ammonium acetate, Betamethasone, High-performance liquid chromatography, Acetic acid, Acetonitrile, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous HPLC determination of butenafine hydrochloride and betamethasone in a cream formulation — Research Paper | ScholarLens