Abstract

Preliminary shielding calculations were performed to establish the dimensions of the radiation shielding surrounding the three Spallation Neutron Source (SNS) beam stops. Steel shielding thicknesses were sized to give dose levels of 1, 2, and 5 mrem/h at the top of the shield, and, to provide enough shielding along the sides and bottom of the beam dump so that soil activation is not a problem. It was concluded that 144 in. of steel shielding is needed above the beam stop. The thickness of the concrete floor in the service building above the dump was not a part of these calculations. This shielding design is current as of January 2000.

Open-access reader

About this research paper

What this paper is about

Preliminary shielding calculations were performed to establish the dimensions of the radiation shielding surrounding the three Spallation Neutron Source (SNS) beam stops. Steel shielding thicknesses were sized to give dose levels of 1, 2, and 5 mrem/h at the top of the shield, and, to provide enough shielding along the sides and bottom of the beam dump so that soil activation is not a problem. It was concluded that 144 in. of steel shielding is needed above the beam stop. The thickness of the concrete floor in the service building above the dump was not a part of these calculations. This shielding design is current as of January 2000.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Preliminary shielding calculations were performed to establish the dimensions of the radiation shielding surrounding the three Spallation Neutron Source (SNS) beam stops. Steel shielding thicknesses were sized to give dose levels of 1, 2, and 5 mrem/h at the top of the shield, and, to provide enough shielding along the sides and bottom of the beam dump so that soil activation is not a problem. It was concluded that 144 in. of steel shielding is needed above the beam stop. The thickness of the concrete floor in the service building above the dump was not a part of these calculations. This shielding design is current as of January 2000.

Key concepts: Electromagnetic shielding, Spallation Neutron Source, Shield, Neutron radiation, Beam (structure), Spallation, Neutron, Radiation shielding

Related papers

Back to paper searchBrowse research topicsOriginal source
Spallation Neutron Source Beam Dump Radiation Shielding Analysis — Research Paper | ScholarLens