2001Catheterization and Cardiovascular InterventionsRequires access

Complications of femoral artery closure devices

Daniel Carey, JoAnn R. Martin, Carl A. Moore, Michael C. Valentine, Thomas W. Nygaard

Open publisher page 172 citations

Abstract

We have examined our prospectively collected experience with femoral artery closure devices. Vasoseal (n = 937), Angioseal (N-742), and Techstar (n = 1001) were utilized consecutively in our laboratory for diagnostic and interventional femoral artery closures. Complications were compared to a similar number of closures with manual compression (MC; n = 1019) before closure devices were utilized. The incidence of surgical repair, acute femoral closure, transfusion due to groin complications, readmission for groin complications, infection, and total complications were examined. We found that the Vasoseal and Angioseal devices were associated with higher rates of total complications than manual compression. The Techstar and manual compression had similar total complication rates. Acute femoral artery occlusion was a potentially serious complication with the Angioseal device. Groin infection occurred with each of the closure devices but not with manual compression.

About this research paper

What this paper is about

We have examined our prospectively collected experience with femoral artery closure devices. Vasoseal (n = 937), Angioseal (N-742), and Techstar (n = 1001) were utilized consecutively in our laboratory for diagnostic and interventional femoral artery closures. Complications were compared to a similar number of closures with manual compression (MC; n = 1019) before closure devices were utilized. The incidence of surgical repair, acute femoral closure, transfusion due to groin complications, readmission for groin complications, infection, and total complications were examined. We found that the Vasoseal and Angioseal devices were associated with higher rates of total complications than manual compression. The Techstar and manual compression had similar total complication rates. Acute femoral artery occlusion was a potentially serious complication with the Angioseal device. Groin infection occurred with each of the closure devices but not with manual compression.

Why it matters

OpenAlex reports 172 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have examined our prospectively collected experience with femoral artery closure devices. Vasoseal (n = 937), Angioseal (N-742), and Techstar (n = 1001) were utilized consecutively in our laboratory for diagnostic and interventional femoral artery closures. Complications were compared to a similar number of closures with manual compression (MC; n = 1019) before closure devices were utilized. The incidence of surgical repair, acute femoral closure, transfusion due to groin complications, readmission for groin complications, infection, and total complications were examined. We found that the Vasoseal and Angioseal devices were associated with higher rates of total complications than manual compression. The Techstar and manual compression had similar total complication rates. Acute femoral artery occlusion was a potentially serious complication with the Angioseal device. Groin infection occurred with each of the closure devices but not with manual compression.

Key concepts: Medicine, Groin, Femoral artery, Surgery, Complication, Vascular closure device, Occlusion, Artery

Related papers

Back to paper searchBrowse research topicsOriginal source
Complications of femoral artery closure devices — Research Paper | ScholarLens