Complications of femoral artery closure devices
Daniel Carey, JoAnn R. Martin, Carl A. Moore, Michael C. Valentine, Thomas W. Nygaard
Abstract
Daniel Carey, JoAnn R. Martin, Carl A. Moore, Michael C. Valentine, Thomas W. Nygaard
Abstract
We have examined our prospectively collected experience with femoral artery closure devices. Vasoseal (n = 937), Angioseal (N-742), and Techstar (n = 1001) were utilized consecutively in our laboratory for diagnostic and interventional femoral artery closures. Complications were compared to a similar number of closures with manual compression (MC; n = 1019) before closure devices were utilized. The incidence of surgical repair, acute femoral closure, transfusion due to groin complications, readmission for groin complications, infection, and total complications were examined. We found that the Vasoseal and Angioseal devices were associated with higher rates of total complications than manual compression. The Techstar and manual compression had similar total complication rates. Acute femoral artery occlusion was a potentially serious complication with the Angioseal device. Groin infection occurred with each of the closure devices but not with manual compression.
OpenAlex reports 172 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
We have examined our prospectively collected experience with femoral artery closure devices. Vasoseal (n = 937), Angioseal (N-742), and Techstar (n = 1001) were utilized consecutively in our laboratory for diagnostic and interventional femoral artery closures. Complications were compared to a similar number of closures with manual compression (MC; n = 1019) before closure devices were utilized. The incidence of surgical repair, acute femoral closure, transfusion due to groin complications, readmission for groin complications, infection, and total complications were examined. We found that the Vasoseal and Angioseal devices were associated with higher rates of total complications than manual compression. The Techstar and manual compression had similar total complication rates. Acute femoral artery occlusion was a potentially serious complication with the Angioseal device. Groin infection occurred with each of the closure devices but not with manual compression.
Key concepts: Medicine, Groin, Femoral artery, Surgery, Complication, Vascular closure device, Occlusion, Artery