2002Environmental Science & TechnologyRequires access

Fouling of Microfiltration and Ultrafiltration Membranes by Natural Waters

Kerry J. Howe, Mark M. Clark

Open publisher page 518 citations

Abstract

Membrane filtration (microfiltration and ultrafiltration) has become an accepted process for drinking water treatment, but membrane fouling remains a significant problem. The objective of this study was to systematically investigate the mechanisms and components in natural waters that contribute to fouling. Natural waters from five sources were filtered in a benchtop filtration system. A sequential filtration process was used in most experiments. The first filtration steps removed specific components from the water, and the latter filtration steps investigated membrane fouling by the remaining components. Particulate matter (larger than 0.45 microm) was relatively unimportant in fouling as compared to dissolved matter. Very small colloids, ranging from about 3-20 nm in diameter, appeared to be important membrane foulants based on this experimental protocol. The colloidal foulants included both inorganic and organic matter, but the greatest fraction of material was organic. When the colloidal fraction of material was removed, the remaining dissolved organic matter (DOM), which was smaller than about 3 nm and included about 85-90% of the total DOM, caused very little fouling. Thus, although other studies have identified DOM as a major foulant during filtration of natural waters, this work shows that a small fraction of DOM may be responsible for fouling. Adsorption was demonstrated to be an important mechanism for fouling by colloids.

About this research paper

What this paper is about

Membrane filtration (microfiltration and ultrafiltration) has become an accepted process for drinking water treatment, but membrane fouling remains a significant problem. The objective of this study was to systematically investigate the mechanisms and components in natural waters that contribute to fouling. Natural waters from five sources were filtered in a benchtop filtration system. A sequential filtration process was used in most experiments. The first filtration steps removed specific components from the water, and the latter filtration steps investigated membrane fouling by the remaining components. Particulate matter (larger than 0.45 microm) was relatively unimportant in fouling as compared to dissolved matter. Very small colloids, ranging from about 3-20 nm in diameter, appeared to be important membrane foulants based on this experimental protocol. The colloidal foulants included both inorganic and organic matter, but the greatest fraction of material was organic. When the colloidal fraction of material was removed, the remaining dissolved organic matter (DOM), which was smaller than about 3 nm and included about 85-90% of the total DOM, caused very little fouling. Thus, although other studies have identified DOM as a major foulant during filtration of natural waters, this work shows that a small fraction of DOM may be responsible for fouling. Adsorption was demonstrated to be an important mechanism for fouling by colloids.

Why it matters

OpenAlex reports 518 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Membrane filtration (microfiltration and ultrafiltration) has become an accepted process for drinking water treatment, but membrane fouling remains a significant problem. The objective of this study was to systematically investigate the mechanisms and components in natural waters that contribute to fouling. Natural waters from five sources were filtered in a benchtop filtration system. A sequential filtration process was used in most experiments. The first filtration steps removed specific components from the water, and the latter filtration steps investigated membrane fouling by the remaining components. Particulate matter (larger than 0.45 microm) was relatively unimportant in fouling as compared to dissolved matter. Very small colloids, ranging from about 3-20 nm in diameter, appeared to be important membrane foulants based on this experimental protocol. The colloidal foulants included both inorganic and organic matter, but the greatest fraction of material was organic. When the colloidal fraction of material was removed, the remaining dissolved organic matter (DOM), which was smaller than about 3 nm and included about 85-90% of the total DOM, caused very little fouling. Thus, although other studies have identified DOM as a major foulant during filtration of natural waters, this work shows that a small fraction of DOM may be responsible for fouling. Adsorption was demonstrated to be an important mechanism for fouling by colloids.

Key concepts: Ultrafiltration (renal), Microfiltration, Fouling, Filtration (mathematics), Membrane fouling, Chemistry, Membrane, Dissolved organic carbon

Related papers

Back to paper searchBrowse research topicsOriginal source
Fouling of Microfiltration and Ultrafiltration Membranes by Natural Waters — Research Paper | ScholarLens