2010Anesthesia & AnalgesiaRequires access

First Clinical Evaluation of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation

Erol Cavus, Tobias Neumann, Volker Doerges, Thora Moeller, Edwin Scharf, Klaus Wagner, Berthold Bein, Goetz Serocki

Open publisher page 132 citations

Abstract

In the present preliminary study we evaluated the C-MAC® D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11 (5-45) seconds and for successful intubation 17 (3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required.

About this research paper

What this paper is about

In the present preliminary study we evaluated the C-MAC® D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11 (5-45) seconds and for successful intubation 17 (3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required.

Why it matters

OpenAlex reports 132 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

In the present preliminary study we evaluated the C-MAC® D-Blade (Karl Storz, Tuttlingen, Germany), a new videolaryngoscopic C-MAC blade for difficult intubation, during both routine and difficult intubations. First, both the conventional direct laryngoscopy and the D-Blade were used in 15 consecutive patients with normal airways during routine induction of anesthesia. Second, the D-Blade was used as a rescue device in 20 of 300 (6.7%) consecutive patients, when conventional direct laryngoscopy failed. In the 15 patients during routine induction of anesthesia, with direct laryngoscopy, a Cormack-Lehane (C/L) grade 1 and grade 2a view was seen in 7 and 8 patients, respectively. It was possible to insert the D-Blade and to get a video view of the glottis on the first attempt in all patients; with the D-Blade, all 15 patients had a C/L 1 view. The time to successful intubation with the D-Blade was 15 (8-26) seconds (median (range)). In the 20 patients, in whom unexpected difficulty with direct laryngoscopy was observed, C/L grades 3 and 4 were present in 15 and 5 patients, respectively. With the use of the D-Blade, indirect C/L video view improved to C/L class 1 in 15 patients, and to 2a in 5 patients, respectively. The time from touching the laryngoscope to optimal laryngoscopic view was 11 (5-45) seconds and for successful intubation 17 (3-80) seconds. In all 35 patients, with the D-Blade no direct view of the glottis was possible and subsequently a semiflexible tube guide was required.

Key concepts: Glottis, Laryngoscopy, Medicine, Intubation, Anesthesia, Tracheal intubation, Blade (archaeology), Laryngoscopes

Related papers

Back to paper searchBrowse research topicsOriginal source
First Clinical Evaluation of the C-MAC D-Blade Videolaryngoscope During Routine and Difficult Intubation — Research Paper | ScholarLens