2007ElectroanalysisRequires access

L ‐Cysteine Voltammetry at a Carbon Paste Electrode Bulk‐Modified with Ferrocenedicarboxylic Acid

Jahan Bakhsh Raoof, Reza Ojani, Hadi Beitollahi

Open publisher page 90 citations

Abstract

Abstract The electrochemical behavior of L‐cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation of L‐cysteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L‐cysteine showed a linear dependent on the L‐cysteine concentration and linear analytical curves were obtained in the ranges of 3.0×10−5 M–2.2×10−3 M and 1.5×10−5 M–3.2×10−3 M of L‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 2.6×10−5 M and 1.4×10−6 M by CV and DPV methods.

About this research paper

What this paper is about

Abstract The electrochemical behavior of L‐cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation of L‐cysteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L‐cysteine showed a linear dependent on the L‐cysteine concentration and linear analytical curves were obtained in the ranges of 3.0×10−5 M–2.2×10−3 M and 1.5×10−5 M–3.2×10−3 M of L‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 2.6×10−5 M and 1.4×10−6 M by CV and DPV methods.

Why it matters

OpenAlex reports 90 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Abstract The electrochemical behavior of L‐cysteine studied at the surface of ferrocenedicarboxylic acid modified carbon paste electrode (FDCMCPE) in aqueous media using cyclic voltammetry, differential pulse voltammetry and double potential step chronoamperometry. It has been found that under optimum condition (pH 8.00) in cyclic voltammetry, the oxidation of L‐cysteine occurs at a potential about 200 mV less positive than that of an unmodified carbon paste electrode. The kinetic parameters such as electron transfer coefficient, α, and catalytic reaction rate constant, kh were also determined using electrochemical approaches. The electrocatalytic oxidation peak current of L‐cysteine showed a linear dependent on the L‐cysteine concentration and linear analytical curves were obtained in the ranges of 3.0×10−5 M–2.2×10−3 M and 1.5×10−5 M–3.2×10−3 M of L‐cysteine concentration with cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods respectively. The detection limits (3σ) were determined as 2.6×10−5 M and 1.4×10−6 M by CV and DPV methods.

Key concepts: Differential pulse voltammetry, Cyclic voltammetry, Chronoamperometry, Chemistry, Voltammetry, Carbon paste electrode, Electrochemistry, Linear sweep voltammetry

Related papers

Back to paper searchBrowse research topicsOriginal source
L ‐Cysteine Voltammetry at a Carbon Paste Electrode Bulk‐Modified with Ferrocenedicarboxylic Acid — Research Paper | ScholarLens