1999Laboratory Robotics and AutomationRequires access

Reversible intermittent flow-injection determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry

Jos� Anchieta Gomes Neto, Luis Fabr�cio Zara, Ademir dos Santos, Júlio César Rocha, Arnaldo Alves Cardoso

Open publisher page 2 citations

Abstract

A reversible intermittent flow-injection procedure is proposed for the automated determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry, CVAAS. Solutions of sample and stannous chloride are carried by two air streams and sequentially injected into the generator/separator chamber in a segmented asynchronous merging zone configuration. The intermittent flow in the forward direction carries the mercury vapor through the flow cell, and in the backward direction, it aspirates the remaining solution from the vessel to waste. We investigated composition and concentration of reagents, flow rates, commutation times, reactor configuration, and conditions for mercury release. The accuracy was checked by mercury determination in a certified sediment and spiked vinasses and river waters. The system handles about 100 samples per hour (0.50–5.00 μg L−1), consuming ca. 2.5 mL of sample and 50 mg of SnCl2 per determination. Good recoveries (92–103%) were obtained with spiked samples. Results are precise (RSD <3% for 2.5 μg Hg L−1, n = 12) and in agreement with values for certified reference material at 95% confidence level. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 304–310, 1999

About this research paper

What this paper is about

A reversible intermittent flow-injection procedure is proposed for the automated determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry, CVAAS. Solutions of sample and stannous chloride are carried by two air streams and sequentially injected into the generator/separator chamber in a segmented asynchronous merging zone configuration. The intermittent flow in the forward direction carries the mercury vapor through the flow cell, and in the backward direction, it aspirates the remaining solution from the vessel to waste. We investigated composition and concentration of reagents, flow rates, commutation times, reactor configuration, and conditions for mercury release. The accuracy was checked by mercury determination in a certified sediment and spiked vinasses and river waters. The system handles about 100 samples per hour (0.50–5.00 μg L−1), consuming ca. 2.5 mL of sample and 50 mg of SnCl2 per determination. Good recoveries (92–103%) were obtained with spiked samples. Results are precise (RSD <3% for 2.5 μg Hg L−1, n = 12) and in agreement with values for certified reference material at 95% confidence level. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 304–310, 1999

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A reversible intermittent flow-injection procedure is proposed for the automated determination of mercury in sediments and vinasses by cold vapor atomic absorption spectrometry, CVAAS. Solutions of sample and stannous chloride are carried by two air streams and sequentially injected into the generator/separator chamber in a segmented asynchronous merging zone configuration. The intermittent flow in the forward direction carries the mercury vapor through the flow cell, and in the backward direction, it aspirates the remaining solution from the vessel to waste. We investigated composition and concentration of reagents, flow rates, commutation times, reactor configuration, and conditions for mercury release. The accuracy was checked by mercury determination in a certified sediment and spiked vinasses and river waters. The system handles about 100 samples per hour (0.50–5.00 μg L−1), consuming ca. 2.5 mL of sample and 50 mg of SnCl2 per determination. Good recoveries (92–103%) were obtained with spiked samples. Results are precise (RSD <3% for 2.5 μg Hg L−1, n = 12) and in agreement with values for certified reference material at 95% confidence level. © 1999 John Wiley & Sons, Inc. Lab Robotics and Automation 11: 304–310, 1999

Key concepts: Mercury (programming language), Chemistry, Cold vapour atomic fluorescence spectroscopy, Atomic absorption spectroscopy, Certified reference materials, Analytical Chemistry (journal), Detection limit, Chromatography