2002•Journal of Near Infrared SpectroscopyRequires access

Using Fourier Transform near Infrared Spectroscopy in Determining Kernel Hardness, Protein and Moisture Content of Whole Wheat Flour

Marena Manley, L. van Zyl, Brian G. Osborne

Open publisher page 70 citations

Abstract

Fourier transform near infrared (FT-NIR) spectroscopy was used successfully to determine the kernel hardness, protein and moisture content of a single sample set of whole wheat flour. The hardness calibration was derived by performing partial least square (PLS) regression on baseline corrected data and using the particle size index (PSI) test as reference method. Both the protein and moisture calibrations were derived by performing PLS regression on multiplicative scatter corrected (MSC) and baseline corrected data. In all cases, the calibration models were subsequently tested by means of independent validation procedures. Good calibration and prediction results were obtained for all three characteristics. Standard error of prediction ( SEP), root mean standard error of prediction ( RMSEP) and correlation coefficient ( r) values of 2.13%, 4.53% and 0.42, respectively, were obtained for the hardness calibration. Corresponding results for the protein and moisture calibrations were 0.51%, 1.16%, 0.81 and 0.15%, 0.38% and 0.85, respectively. The FT-NIR protein and moisture results of this study compare satisfactorily with results achieved in previous FT-NIR studies. No other FT-NIR wheat hardness results have been reported elsewhere, but results of this study compare well to those achieved in other NIR wheat hardness studies.

About this research paper

What this paper is about

Fourier transform near infrared (FT-NIR) spectroscopy was used successfully to determine the kernel hardness, protein and moisture content of a single sample set of whole wheat flour. The hardness calibration was derived by performing partial least square (PLS) regression on baseline corrected data and using the particle size index (PSI) test as reference method. Both the protein and moisture calibrations were derived by performing PLS regression on multiplicative scatter corrected (MSC) and baseline corrected data. In all cases, the calibration models were subsequently tested by means of independent validation procedures. Good calibration and prediction results were obtained for all three characteristics. Standard error of prediction ( SEP), root mean standard error of prediction ( RMSEP) and correlation coefficient ( r) values of 2.13%, 4.53% and 0.42, respectively, were obtained for the hardness calibration. Corresponding results for the protein and moisture calibrations were 0.51%, 1.16%, 0.81 and 0.15%, 0.38% and 0.85, respectively. The FT-NIR protein and moisture results of this study compare satisfactorily with results achieved in previous FT-NIR studies. No other FT-NIR wheat hardness results have been reported elsewhere, but results of this study compare well to those achieved in other NIR wheat hardness studies.

Why it matters

OpenAlex reports 70 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Fourier transform near infrared (FT-NIR) spectroscopy was used successfully to determine the kernel hardness, protein and moisture content of a single sample set of whole wheat flour. The hardness calibration was derived by performing partial least square (PLS) regression on baseline corrected data and using the particle size index (PSI) test as reference method. Both the protein and moisture calibrations were derived by performing PLS regression on multiplicative scatter corrected (MSC) and baseline corrected data. In all cases, the calibration models were subsequently tested by means of independent validation procedures. Good calibration and prediction results were obtained for all three characteristics. Standard error of prediction ( SEP), root mean standard error of prediction ( RMSEP) and correlation coefficient ( r) values of 2.13%, 4.53% and 0.42, respectively, were obtained for the hardness calibration. Corresponding results for the protein and moisture calibrations were 0.51%, 1.16%, 0.81 and 0.15%, 0.38% and 0.85, respectively. The FT-NIR protein and moisture results of this study compare satisfactorily with results achieved in previous FT-NIR studies. No other FT-NIR wheat hardness results have been reported elsewhere, but results of this study compare well to those achieved in other NIR wheat hardness studies.

Key concepts: Calibration, Near-infrared spectroscopy, Partial least squares regression, Standard error, Moisture, Mathematics, Analytical Chemistry (journal), Coefficient of determination

Related papers

Back to paper searchBrowse research topicsOriginal source
Using Fourier Transform near Infrared Spectroscopy in Determining Kernel Hardness, Protein and Moisture Content of Whole Wheat Flour — Research Paper | ScholarLens