Colorimetry-based retardation measurement method with white-light interference
Carole C. Montarou, Thomas K. Gaylord, Ricardo A. Villalaz, Elias N. Glytsis
Abstract
Carole C. Montarou, Thomas K. Gaylord, Ricardo A. Villalaz, Elias N. Glytsis
Abstract
A colorimetry-based retardation measurement (CBRM) method is presented. The specimen, between crossed polarizers, is illuminated with a white-light source. The retardation that is due to the birefringence of the specimen produces a white-light interference color. The x, y chromaticity coordinates of the color produced are measured with a spectrophotometer. The resulting x, y values are compared with a retardation x, y database that we obtained by measuring the retardation with an accurate Senarmont compensator and the x, y chromaticity values along the length of a 0-4-order quartz wedge. The technique was validated by the measurement of a variety of retardation plates. The retardation accuracy (mean error) of the CBRM method is shown to be 3.6 nm. The resolution is +/-0.2 nm, and the measurement range is 5-2150 nm. The method substitutes for a polariscope and eliminates errors associated with quarter-wave plates. The CBRM method does not utilize any moving parts and thus is fast and can be automated.
OpenAlex reports 7 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A colorimetry-based retardation measurement (CBRM) method is presented. The specimen, between crossed polarizers, is illuminated with a white-light source. The retardation that is due to the birefringence of the specimen produces a white-light interference color. The x, y chromaticity coordinates of the color produced are measured with a spectrophotometer. The resulting x, y values are compared with a retardation x, y database that we obtained by measuring the retardation with an accurate Senarmont compensator and the x, y chromaticity values along the length of a 0-4-order quartz wedge. The technique was validated by the measurement of a variety of retardation plates. The retardation accuracy (mean error) of the CBRM method is shown to be 3.6 nm. The resolution is +/-0.2 nm, and the measurement range is 5-2150 nm. The method substitutes for a polariscope and eliminates errors associated with quarter-wave plates. The CBRM method does not utilize any moving parts and thus is fast and can be automated.
Key concepts: Chromaticity, Optics, Polarizer, Colorimetry, Materials science, Birefringence, Interference (communication), White light