2013PLoS ONEOpen access

Feasibility of Performing Multiple Point of Care Testing for HIV Anti-Retroviral Treatment Initiation and Monitoring from Multiple or Single Fingersticks

Natasha M. Gous, Lesley Erica Scott, J Potgieter, Lumka Ntabeni, Sharon Enslin, Ronel Newman, Wendy Susan Stevens

Open full text 27 citations

Abstract

BACKGROUND: Point of Care testing (POCT) provides on-site, rapid, accessible results. With current South African anti-retroviral treatment guidelines, up to 4 fingersticks /patient/clinic visit could be required if utilizing POC. We determined the feasibility and accuracy of a nurse performing multiple POCT on multiple fingersticks followed by simplification of the process by performance of multiple POC on a single fingerstick. METHOD AND FINDINGS: Random HIV positive adult patients presenting at a HIV treatment clinic in South Africa, for ART initiation/ monitoring, were approached to participate in the study between April-June 2012. Phase I: n=150 patients approached for multiple POCT on multiple fingersticks. Phase II: n=150 patients approached for multiple POCT on a single fingerstick. The following POC tests were performed by a dedicated nurse: PIMA (CD4), HemoCue (hemoglobin), Reflotron (alanine aminotransferase, creatinine). A venepuncture specimen was taken for predicate laboratory methodology. Normal laboratory ranges and Royal College of Pathologists Australasia (RCPA) allowable differences were used as guidelines for comparison. In 67% of participants, ≥3 tests were requested per visit. All POCT were accurate but ranged in variability. Phase I: Hemoglobin was accurate (3.2%CV) while CD4, alanine aminotransferase and creatinine showed increased variability (16.3%CV; 9.3%CV; 12.9%CV respectively). PIMA generated a misclassification of 12.4%. Phase II: Hemoglobin, alanine aminotransferase and creatinine showed good accuracy (3.2%CV, 8.7%CV, 6.4%CV respectively) with increased variability on CD4 (12.4%CV) but low clinical misclassification (4.1%). No trends were observed for the sequence in which POC was performed on a single fingerstick. Overall, PIMA CD4 generated the highest error rate (16-19%). CONCLUSIONS: Multiple POCT for ART initiation and/or monitoring can be performed practically by a dedicated nurse on multiple fingersticks. The process is as accurate as predicate methodology and can be simplified using a single fingerstick.

Open-access reader

About this research paper

What this paper is about

BACKGROUND: Point of Care testing (POCT) provides on-site, rapid, accessible results. With current South African anti-retroviral treatment guidelines, up to 4 fingersticks /patient/clinic visit could be required if utilizing POC. We determined the feasibility and accuracy of a nurse performing multiple POCT on multiple fingersticks followed by simplification of the process by performance of multiple POC on a single fingerstick. METHOD AND FINDINGS: Random HIV positive adult patients presenting at a HIV treatment clinic in South Africa, for ART initiation/ monitoring, were approached to participate in the study between April-June 2012. Phase I: n=150 patients approached for multiple POCT on multiple fingersticks. Phase II: n=150 patients approached for multiple POCT on a single fingerstick. The following POC tests were performed by a dedicated nurse: PIMA (CD4), HemoCue (hemoglobin), Reflotron (alanine aminotransferase, creatinine). A venepuncture specimen was taken for predicate laboratory methodology. Normal laboratory ranges and Royal College of Pathologists Australasia (RCPA) allowable differences were used as guidelines for comparison. In 67% of participants, ≥3 tests were requested per visit. All POCT were accurate but ranged in variability. Phase I: Hemoglobin was accurate (3.2%CV) while CD4, alanine aminotransferase and creatinine showed increased variability (16.3%CV; 9.3%CV; 12.9%CV respectively). PIMA generated a misclassification of 12.4%. Phase II: Hemoglobin, alanine aminotransferase and creatinine showed good accuracy (3.2%CV, 8.7%CV, 6.4%CV respectively) with increased variability on CD4 (12.4%CV) but low clinical misclassification (4.1%). No trends were observed for the sequence in which POC was performed on a single fingerstick. Overall, PIMA CD4 generated the highest error rate (16-19%). CONCLUSIONS: Multiple POCT for ART initiation and/or monitoring can be performed practically by a dedicated nurse on multiple fingersticks. The process is as accurate as predicate methodology and can be simplified using a single fingerstick.

Why it matters

OpenAlex reports 27 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

BACKGROUND: Point of Care testing (POCT) provides on-site, rapid, accessible results. With current South African anti-retroviral treatment guidelines, up to 4 fingersticks /patient/clinic visit could be required if utilizing POC. We determined the feasibility and accuracy of a nurse performing multiple POCT on multiple fingersticks followed by simplification of the process by performance of multiple POC on a single fingerstick. METHOD AND FINDINGS: Random HIV positive adult patients presenting at a HIV treatment clinic in South Africa, for ART initiation/ monitoring, were approached to participate in the study between April-June 2012. Phase I: n=150 patients approached for multiple POCT on multiple fingersticks. Phase II: n=150 patients approached for multiple POCT on a single fingerstick. The following POC tests were performed by a dedicated nurse: PIMA (CD4), HemoCue (hemoglobin), Reflotron (alanine aminotransferase, creatinine). A venepuncture specimen was taken for predicate laboratory methodology. Normal laboratory ranges and Royal College of Pathologists Australasia (RCPA) allowable differences were used as guidelines for comparison. In 67% of participants, ≥3 tests were requested per visit. All POCT were accurate but ranged in variability. Phase I: Hemoglobin was accurate (3.2%CV) while CD4, alanine aminotransferase and creatinine showed increased variability (16.3%CV; 9.3%CV; 12.9%CV respectively). PIMA generated a misclassification of 12.4%. Phase II: Hemoglobin, alanine aminotransferase and creatinine showed good accuracy (3.2%CV, 8.7%CV, 6.4%CV respectively) with increased variability on CD4 (12.4%CV) but low clinical misclassification (4.1%). No trends were observed for the sequence in which POC was performed on a single fingerstick. Overall, PIMA CD4 generated the highest error rate (16-19%). CONCLUSIONS: Multiple POCT for ART initiation and/or monitoring can be performed practically by a dedicated nurse on multiple fingersticks. The process is as accurate as predicate methodology and can be simplified using a single fingerstick.

Key concepts: Fingerstick, Point-of-care testing, Medicine, Creatinine, Venipuncture, Alanine aminotransferase, Point of care, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Feasibility of Performing Multiple Point of Care Testing for HIV Anti-Retroviral Treatment Initiation and Monitoring from Multiple or Single Fingersticks — Research Paper | ScholarLens