2012International Journal of Geotechnical Earthquake EngineeringRequires access

Liquefaction and Pore Water Pressure Generation in Sand

T. G. Sitharam, B. V. Ravishankar, S. M. Patil

Open publisher page 20 citations

Abstract

Cyclic strain controlled laboratory triaxial undrained tests were performed on sand samples collected from earthquake affected Ahmedabad City of Gujarat (India). To study the factors controlling the liquefaction potential and pore pressure generation, cyclic strain controlled triaxial tests were carried out on (a) base sand, (b) pure sand, and (c) pure sand and non plastic silt mixture. All the tests were conducted on reconstituted soil samples and consolidated isotropically to different effective confining pressures. Base sand, clean sand and sand with non-plastic fines were tested using cyclic strain controlled triaxial undrained tests for different combination of shear strain amplitudes, initial effective confining pressure, and relative density (RD). In case of base sand and pure sand both have qualitatively the same liquefaction and pore pressure generation behaviors. For sand with non plastic fines, basic concept of limiting fines content (LFC) is justified and shown that how the behavior of mixture undergoes transition before and after LFC. This transitional behavior is observed both in the liquefaction strength and pore pressure generation. To obtain a mean relationship between liquefaction strength, pore pressure generation on relative density, confining pressure and shear strain amplitude, approaches previously adopted by Talaganov (1996) are used.

About this research paper

What this paper is about

Cyclic strain controlled laboratory triaxial undrained tests were performed on sand samples collected from earthquake affected Ahmedabad City of Gujarat (India). To study the factors controlling the liquefaction potential and pore pressure generation, cyclic strain controlled triaxial tests were carried out on (a) base sand, (b) pure sand, and (c) pure sand and non plastic silt mixture. All the tests were conducted on reconstituted soil samples and consolidated isotropically to different effective confining pressures. Base sand, clean sand and sand with non-plastic fines were tested using cyclic strain controlled triaxial undrained tests for different combination of shear strain amplitudes, initial effective confining pressure, and relative density (RD). In case of base sand and pure sand both have qualitatively the same liquefaction and pore pressure generation behaviors. For sand with non plastic fines, basic concept of limiting fines content (LFC) is justified and shown that how the behavior of mixture undergoes transition before and after LFC. This transitional behavior is observed both in the liquefaction strength and pore pressure generation. To obtain a mean relationship between liquefaction strength, pore pressure generation on relative density, confining pressure and shear strain amplitude, approaches previously adopted by Talaganov (1996) are used.

Why it matters

OpenAlex reports 20 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Cyclic strain controlled laboratory triaxial undrained tests were performed on sand samples collected from earthquake affected Ahmedabad City of Gujarat (India). To study the factors controlling the liquefaction potential and pore pressure generation, cyclic strain controlled triaxial tests were carried out on (a) base sand, (b) pure sand, and (c) pure sand and non plastic silt mixture. All the tests were conducted on reconstituted soil samples and consolidated isotropically to different effective confining pressures. Base sand, clean sand and sand with non-plastic fines were tested using cyclic strain controlled triaxial undrained tests for different combination of shear strain amplitudes, initial effective confining pressure, and relative density (RD). In case of base sand and pure sand both have qualitatively the same liquefaction and pore pressure generation behaviors. For sand with non plastic fines, basic concept of limiting fines content (LFC) is justified and shown that how the behavior of mixture undergoes transition before and after LFC. This transitional behavior is observed both in the liquefaction strength and pore pressure generation. To obtain a mean relationship between liquefaction strength, pore pressure generation on relative density, confining pressure and shear strain amplitude, approaches previously adopted by Talaganov (1996) are used.

Key concepts: Liquefaction, Pore water pressure, Geotechnical engineering, Silt, Overburden pressure, Relative density, Triaxial shear test, Shear (geology)