2001American Journal of Medical GeneticsRequires access

Efficient detection of alport syndromeCOL4a5 mutations with multiplex genomic PCR-SSCP

David F. Barker, Joyce C. Denison, Curtis L. Atkin, Martin C. Gregory

Open publisher page 44 citations

Abstract

We have performed effective mutation screening of COL4A5 with a new method of direct, multiplex genomic amplification that employs a single buffer condition and PCR profile. Application of the method to a consecutive series of 46 United States patients with diverse indications of Alport syndrome resulted in detection of mutations in 31 cases and of five previously unreported polymorphisms. With a correction for the presence of cases that are not likely to be due to changes at the COL4A5 locus, the mutation detection sensitivity is greater than 79%. The test examines 52 segments, including the COL4A6/COL4A5 intergenic promoter region, all 51 of the previously recognized exons and two newly detected exons between exons 41 and 42 that encode an alternatively spliced mRNA segment. New genomic sequence information was generated and used to design primer pairs that span substantial intron sequences on each side of all 53 exons. For SSCP screening, 16 multiplex PCR combinations (15 4-plex and 1 3-plex) were used to provide complete, partially redundant coverage of the gene. The selected combinations allow clear resolution of products from each segment using various SSCP gel formulations. One of the 29 different mutations detected initially seemed to be a missense change in exon 32 but was found to cause exon skipping. Another missense variant may mark a novel functional site located in the collagenous domain.

About this research paper

What this paper is about

We have performed effective mutation screening of COL4A5 with a new method of direct, multiplex genomic amplification that employs a single buffer condition and PCR profile. Application of the method to a consecutive series of 46 United States patients with diverse indications of Alport syndrome resulted in detection of mutations in 31 cases and of five previously unreported polymorphisms. With a correction for the presence of cases that are not likely to be due to changes at the COL4A5 locus, the mutation detection sensitivity is greater than 79%. The test examines 52 segments, including the COL4A6/COL4A5 intergenic promoter region, all 51 of the previously recognized exons and two newly detected exons between exons 41 and 42 that encode an alternatively spliced mRNA segment. New genomic sequence information was generated and used to design primer pairs that span substantial intron sequences on each side of all 53 exons. For SSCP screening, 16 multiplex PCR combinations (15 4-plex and 1 3-plex) were used to provide complete, partially redundant coverage of the gene. The selected combinations allow clear resolution of products from each segment using various SSCP gel formulations. One of the 29 different mutations detected initially seemed to be a missense change in exon 32 but was found to cause exon skipping. Another missense variant may mark a novel functional site located in the collagenous domain.

Why it matters

OpenAlex reports 44 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

We have performed effective mutation screening of COL4A5 with a new method of direct, multiplex genomic amplification that employs a single buffer condition and PCR profile. Application of the method to a consecutive series of 46 United States patients with diverse indications of Alport syndrome resulted in detection of mutations in 31 cases and of five previously unreported polymorphisms. With a correction for the presence of cases that are not likely to be due to changes at the COL4A5 locus, the mutation detection sensitivity is greater than 79%. The test examines 52 segments, including the COL4A6/COL4A5 intergenic promoter region, all 51 of the previously recognized exons and two newly detected exons between exons 41 and 42 that encode an alternatively spliced mRNA segment. New genomic sequence information was generated and used to design primer pairs that span substantial intron sequences on each side of all 53 exons. For SSCP screening, 16 multiplex PCR combinations (15 4-plex and 1 3-plex) were used to provide complete, partially redundant coverage of the gene. The selected combinations allow clear resolution of products from each segment using various SSCP gel formulations. One of the 29 different mutations detected initially seemed to be a missense change in exon 32 but was found to cause exon skipping. Another missense variant may mark a novel functional site located in the collagenous domain.

Key concepts: Exon, Genetics, Biology, Missense mutation, genomic DNA, Alport syndrome, Single-strand conformation polymorphism, Locus (genetics)

Related papers

Back to paper searchBrowse research topicsOriginal source
Efficient detection of alport syndromeCOL4a5 mutations with multiplex genomic PCR-SSCP — Research Paper | ScholarLens