1997Dental TraumatologyRequires access

Accuracy of apex locator

La-ongthong Vajrabhaya, P Tepmongkol

Open publisher page 55 citations

Abstract

An evaluation of the accuracy of the "Root ZX" apex locator was conducted on 20 single-rooted teeth that had been extracted because of severe disease or orthodontic treatment. After the pulp chamber had been accessed and the tooth length determined using the Root ZX apparatus, the file was fixed to the tooth with light-cured composite resin. After extraction, the tooth was longitudinally ground with a diamond bur until the file was visible. The distance between the file tip and the apical foramen was measured under a microscope (x 100). The results showed that the tip of the instrument reached the apical foramen in all teeth.

About this research paper

What this paper is about

An evaluation of the accuracy of the "Root ZX" apex locator was conducted on 20 single-rooted teeth that had been extracted because of severe disease or orthodontic treatment. After the pulp chamber had been accessed and the tooth length determined using the Root ZX apparatus, the file was fixed to the tooth with light-cured composite resin. After extraction, the tooth was longitudinally ground with a diamond bur until the file was visible. The distance between the file tip and the apical foramen was measured under a microscope (x 100). The results showed that the tip of the instrument reached the apical foramen in all teeth.

Why it matters

OpenAlex reports 55 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

An evaluation of the accuracy of the "Root ZX" apex locator was conducted on 20 single-rooted teeth that had been extracted because of severe disease or orthodontic treatment. After the pulp chamber had been accessed and the tooth length determined using the Root ZX apparatus, the file was fixed to the tooth with light-cured composite resin. After extraction, the tooth was longitudinally ground with a diamond bur until the file was visible. The distance between the file tip and the apical foramen was measured under a microscope (x 100). The results showed that the tip of the instrument reached the apical foramen in all teeth.

Key concepts: Apical foramen, Apex (geometry), Foramen, Pulp (tooth), Dentistry, Orthodontics, Medicine, Materials science