2014Unpublished venueRequires access

Underground Ground wires for transmission lines: Electrical behavior and feasibility

Janne Seppänen, Paavo Tammi, Liisa Haarla

Open publisher page 2 citations

Abstract

Icing of overhead ground wires on transmission lines may result in faults and widespread power outages. This paper investigates the feasibility of an unconventional overhead line structure that is equipped with underground rather than overhead ground wires to prevent faults caused by icing. The underground ground wire is a buried bare conductor connected to the grounding of each transmission-line tower. To analyze the ground fault of the overhead line structure, this paper derives analytical equations to evaluate the current and potential distribution in the underground ground wire, earth surface potential around the wire, and grounding impedance of the faulted tower. The validity of the presented equations is verified by measurements. Based on the ground fault analysis, this paper evaluates the electrical safety of the discussed overhead line structure. Lightning shielding of overhead lines is not considered in this paper.

About this research paper

What this paper is about

Icing of overhead ground wires on transmission lines may result in faults and widespread power outages. This paper investigates the feasibility of an unconventional overhead line structure that is equipped with underground rather than overhead ground wires to prevent faults caused by icing. The underground ground wire is a buried bare conductor connected to the grounding of each transmission-line tower. To analyze the ground fault of the overhead line structure, this paper derives analytical equations to evaluate the current and potential distribution in the underground ground wire, earth surface potential around the wire, and grounding impedance of the faulted tower. The validity of the presented equations is verified by measurements. Based on the ground fault analysis, this paper evaluates the electrical safety of the discussed overhead line structure. Lightning shielding of overhead lines is not considered in this paper.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Icing of overhead ground wires on transmission lines may result in faults and widespread power outages. This paper investigates the feasibility of an unconventional overhead line structure that is equipped with underground rather than overhead ground wires to prevent faults caused by icing. The underground ground wire is a buried bare conductor connected to the grounding of each transmission-line tower. To analyze the ground fault of the overhead line structure, this paper derives analytical equations to evaluate the current and potential distribution in the underground ground wire, earth surface potential around the wire, and grounding impedance of the faulted tower. The validity of the presented equations is verified by measurements. Based on the ground fault analysis, this paper evaluates the electrical safety of the discussed overhead line structure. Lightning shielding of overhead lines is not considered in this paper.

Key concepts: Ground, Electric power transmission, Overhead (engineering), Lightning (connector), Overhead line, Electrical conductor, Transmission line, Fault (geology)

Related papers

Back to paper searchBrowse research topicsOriginal source
Underground Ground wires for transmission lines: Electrical behavior and feasibility — Research Paper | ScholarLens