Underground Ground wires for transmission lines: Electrical behavior and feasibility
Janne Seppänen, Paavo Tammi, Liisa Haarla
Abstract
Janne Seppänen, Paavo Tammi, Liisa Haarla
Abstract
Icing of overhead ground wires on transmission lines may result in faults and widespread power outages. This paper investigates the feasibility of an unconventional overhead line structure that is equipped with underground rather than overhead ground wires to prevent faults caused by icing. The underground ground wire is a buried bare conductor connected to the grounding of each transmission-line tower. To analyze the ground fault of the overhead line structure, this paper derives analytical equations to evaluate the current and potential distribution in the underground ground wire, earth surface potential around the wire, and grounding impedance of the faulted tower. The validity of the presented equations is verified by measurements. Based on the ground fault analysis, this paper evaluates the electrical safety of the discussed overhead line structure. Lightning shielding of overhead lines is not considered in this paper.
OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Icing of overhead ground wires on transmission lines may result in faults and widespread power outages. This paper investigates the feasibility of an unconventional overhead line structure that is equipped with underground rather than overhead ground wires to prevent faults caused by icing. The underground ground wire is a buried bare conductor connected to the grounding of each transmission-line tower. To analyze the ground fault of the overhead line structure, this paper derives analytical equations to evaluate the current and potential distribution in the underground ground wire, earth surface potential around the wire, and grounding impedance of the faulted tower. The validity of the presented equations is verified by measurements. Based on the ground fault analysis, this paper evaluates the electrical safety of the discussed overhead line structure. Lightning shielding of overhead lines is not considered in this paper.
Key concepts: Ground, Electric power transmission, Overhead (engineering), Lightning (connector), Overhead line, Electrical conductor, Transmission line, Fault (geology)