1999Physical review. E, Statistical physics, plasmas, fluids, and related interdisciplinary topicsRequires access

Cyclotron-resonance maser in a magnetic mirror

Ronen Caspi, E. Jerby

Open publisher page 3 citations

Abstract

A cyclotron-resonance maser (CRM) experiment is performed in a high-gradient magnetic field using a low-energy electron beam ( approximately 10 keV/1 A). The magnetic field exceeds 1.63 T, which corresponds to a 45-GHz cyclotron frequency. The CRM radiation output is observed in much lower frequencies, between 6.6 and 20 GHz only. This discrepancy is explained by the finite penetration depth of the electrons into the growing magnetic field, as in a magnetic mirror. The electrons emit radiation at the local cyclotron frequency in their reflection point from that magnetic mirror; hence, the radiation frequency depends mostly on the initial electron energy. A conceptual reflex gyrotron scheme is proposed in this paper, as a CRM analogue for the known reflex klystron.

About this research paper

What this paper is about

A cyclotron-resonance maser (CRM) experiment is performed in a high-gradient magnetic field using a low-energy electron beam ( approximately 10 keV/1 A). The magnetic field exceeds 1.63 T, which corresponds to a 45-GHz cyclotron frequency. The CRM radiation output is observed in much lower frequencies, between 6.6 and 20 GHz only. This discrepancy is explained by the finite penetration depth of the electrons into the growing magnetic field, as in a magnetic mirror. The electrons emit radiation at the local cyclotron frequency in their reflection point from that magnetic mirror; hence, the radiation frequency depends mostly on the initial electron energy. A conceptual reflex gyrotron scheme is proposed in this paper, as a CRM analogue for the known reflex klystron.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A cyclotron-resonance maser (CRM) experiment is performed in a high-gradient magnetic field using a low-energy electron beam ( approximately 10 keV/1 A). The magnetic field exceeds 1.63 T, which corresponds to a 45-GHz cyclotron frequency. The CRM radiation output is observed in much lower frequencies, between 6.6 and 20 GHz only. This discrepancy is explained by the finite penetration depth of the electrons into the growing magnetic field, as in a magnetic mirror. The electrons emit radiation at the local cyclotron frequency in their reflection point from that magnetic mirror; hence, the radiation frequency depends mostly on the initial electron energy. A conceptual reflex gyrotron scheme is proposed in this paper, as a CRM analogue for the known reflex klystron.

Key concepts: Maser, Physics, Cyclotron resonance, Cyclotron, Electron cyclotron resonance, Cyclotron radiation, Magnetic field, Electron

Related papers

Back to paper searchBrowse research topicsOriginal source
Cyclotron-resonance maser in a magnetic mirror — Research Paper | ScholarLens