2013Unpublished venueRequires access

A new method to estimate sound energy entering the middle ear

Shixiong Chen, Deng Jun, Lin Bian, Guanglin Li

Open publisher page 2 citations

Abstract

Standing waves in the ear canal can cause inaccurate quantification of the sound pressure level (SPL) entering the ear and therefore lead to unreliable results in clinical tests. Since it is impractical to directly measure the SPL at the eardrum position, in this study we proposed a new method to estimate the eardrum SPL by solely making measurement at the entry of the ear canal. To achieve this, the acoustic characteristics of the earphone were calculated using a calculation tube with variable lengths. Then the ear canal impedance was calculated according to the obtained source characteristics. Finally, the eardrum SPL was estimated by the ear-canal impedance and the SPL measured at the entry of the ear canal. The results showed that the eardrum SPL could be reliably estimated for all the five subjects participated in this study. The maximal estimation error was less than 3 dB for all frequencies from 0.5 to 10 kHz. These findings suggested that the proposed method could avoid the standing wave problem and therefore might be a great candidate for accurate calibration of sound pressure in various acoustic measurements.

About this research paper

What this paper is about

Standing waves in the ear canal can cause inaccurate quantification of the sound pressure level (SPL) entering the ear and therefore lead to unreliable results in clinical tests. Since it is impractical to directly measure the SPL at the eardrum position, in this study we proposed a new method to estimate the eardrum SPL by solely making measurement at the entry of the ear canal. To achieve this, the acoustic characteristics of the earphone were calculated using a calculation tube with variable lengths. Then the ear canal impedance was calculated according to the obtained source characteristics. Finally, the eardrum SPL was estimated by the ear-canal impedance and the SPL measured at the entry of the ear canal. The results showed that the eardrum SPL could be reliably estimated for all the five subjects participated in this study. The maximal estimation error was less than 3 dB for all frequencies from 0.5 to 10 kHz. These findings suggested that the proposed method could avoid the standing wave problem and therefore might be a great candidate for accurate calibration of sound pressure in various acoustic measurements.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Standing waves in the ear canal can cause inaccurate quantification of the sound pressure level (SPL) entering the ear and therefore lead to unreliable results in clinical tests. Since it is impractical to directly measure the SPL at the eardrum position, in this study we proposed a new method to estimate the eardrum SPL by solely making measurement at the entry of the ear canal. To achieve this, the acoustic characteristics of the earphone were calculated using a calculation tube with variable lengths. Then the ear canal impedance was calculated according to the obtained source characteristics. Finally, the eardrum SPL was estimated by the ear-canal impedance and the SPL measured at the entry of the ear canal. The results showed that the eardrum SPL could be reliably estimated for all the five subjects participated in this study. The maximal estimation error was less than 3 dB for all frequencies from 0.5 to 10 kHz. These findings suggested that the proposed method could avoid the standing wave problem and therefore might be a great candidate for accurate calibration of sound pressure in various acoustic measurements.

Key concepts: Eardrum, Ear canal, Acoustics, Sound pressure, Middle ear, Acoustic impedance, Position (finance), Electrical impedance

Related papers

Back to paper searchBrowse research topicsOriginal source
A new method to estimate sound energy entering the middle ear — Research Paper | ScholarLens