1992Journal of Liquid ChromatographyRequires access

Some Retention Characteristics of Dipeptides in Reversed-Phase High Performance Liquid Chromatography

Hanfa Zou, Yukui Zhang, Minfang Hong, Peichang Lu

Open publisher page 3 citations

Abstract

The effect of hydrophobicity of amino acid subunits on the retention of dipeptides with phosphate buffer as the eluent in RP-HPLC was studied, it has been observed that the capacity factor for dipeptides combined of amino acid subunits with hydrophobicity smaller than that of Ala is smaller than 0.4, and these dipeptides had better be separated by reversed-phase ion-pair liquid chromatography or ion chromatography. Otherwise, the dipeptides combined of amino acid subunits with hydrophobicity larger than that of Ala can be separated by RP-HPLC. It has been observed that there is a good linear relationship between Ink' values in RP-HPLC with the same eluent and different packing materials used or the same packing material and different eluents containing low concentration of different organic modifiers used.

About this research paper

What this paper is about

The effect of hydrophobicity of amino acid subunits on the retention of dipeptides with phosphate buffer as the eluent in RP-HPLC was studied, it has been observed that the capacity factor for dipeptides combined of amino acid subunits with hydrophobicity smaller than that of Ala is smaller than 0.4, and these dipeptides had better be separated by reversed-phase ion-pair liquid chromatography or ion chromatography. Otherwise, the dipeptides combined of amino acid subunits with hydrophobicity larger than that of Ala can be separated by RP-HPLC. It has been observed that there is a good linear relationship between Ink' values in RP-HPLC with the same eluent and different packing materials used or the same packing material and different eluents containing low concentration of different organic modifiers used.

Why it matters

OpenAlex reports 3 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The effect of hydrophobicity of amino acid subunits on the retention of dipeptides with phosphate buffer as the eluent in RP-HPLC was studied, it has been observed that the capacity factor for dipeptides combined of amino acid subunits with hydrophobicity smaller than that of Ala is smaller than 0.4, and these dipeptides had better be separated by reversed-phase ion-pair liquid chromatography or ion chromatography. Otherwise, the dipeptides combined of amino acid subunits with hydrophobicity larger than that of Ala can be separated by RP-HPLC. It has been observed that there is a good linear relationship between Ink' values in RP-HPLC with the same eluent and different packing materials used or the same packing material and different eluents containing low concentration of different organic modifiers used.

Key concepts: High-performance liquid chromatography, Chromatography, Chemistry, Column chromatography, Reversed-phase chromatography, Amino acid, Phosphate buffered saline, Capacity factor

Related papers

Back to paper searchBrowse research topicsOriginal source
Some Retention Characteristics of Dipeptides in Reversed-Phase High Performance Liquid Chromatography — Research Paper | ScholarLens