1994PubMedRequires access

Cholesterol in fingerstick capillary specimens can be equivalent to conventional venous measurements.

G R Warnick, Elizabeth Teng Leary, Enrico Ammirati, Morrette Allen

Open publisher page 23 citations

Abstract

Current interest in coronary heart disease and cholesterol has led to the development of a new generation of compact analysis systems designed for fingerstick whole blood measurement. Since reliable classification of patients based on national cut-points for serum cholesterol concentration requires accurate results, the question whether results from fingerstick capillary specimens are equivalent to those from conventional venous-derived serum specimens, the basis for the national cut-points, is germane. Earlier studies in the literature are contradictory, with fingerstick differences ranging from 9% low to 6% high. We developed guidelines for reliable fingerstick collection and, following these guidelines, achieved results that were comparable to results derived from concurrently collected venous serum specimens. Results measured either by an accurate, standardized enzymatic assay or by the AccuMeter, a new noninstrumented device, were in close agreement with serum results, ie, within 1% and 1.7%, respectively, suggesting that fingerstick measurements are appropriate for identifying individuals with elevated cholesterol levels and monitoring their treatment.

About this research paper

What this paper is about

Current interest in coronary heart disease and cholesterol has led to the development of a new generation of compact analysis systems designed for fingerstick whole blood measurement. Since reliable classification of patients based on national cut-points for serum cholesterol concentration requires accurate results, the question whether results from fingerstick capillary specimens are equivalent to those from conventional venous-derived serum specimens, the basis for the national cut-points, is germane. Earlier studies in the literature are contradictory, with fingerstick differences ranging from 9% low to 6% high. We developed guidelines for reliable fingerstick collection and, following these guidelines, achieved results that were comparable to results derived from concurrently collected venous serum specimens. Results measured either by an accurate, standardized enzymatic assay or by the AccuMeter, a new noninstrumented device, were in close agreement with serum results, ie, within 1% and 1.7%, respectively, suggesting that fingerstick measurements are appropriate for identifying individuals with elevated cholesterol levels and monitoring their treatment.

Why it matters

OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Current interest in coronary heart disease and cholesterol has led to the development of a new generation of compact analysis systems designed for fingerstick whole blood measurement. Since reliable classification of patients based on national cut-points for serum cholesterol concentration requires accurate results, the question whether results from fingerstick capillary specimens are equivalent to those from conventional venous-derived serum specimens, the basis for the national cut-points, is germane. Earlier studies in the literature are contradictory, with fingerstick differences ranging from 9% low to 6% high. We developed guidelines for reliable fingerstick collection and, following these guidelines, achieved results that were comparable to results derived from concurrently collected venous serum specimens. Results measured either by an accurate, standardized enzymatic assay or by the AccuMeter, a new noninstrumented device, were in close agreement with serum results, ie, within 1% and 1.7%, respectively, suggesting that fingerstick measurements are appropriate for identifying individuals with elevated cholesterol levels and monitoring their treatment.

Key concepts: Fingerstick, Medicine, Venous blood, Cholesterol, Internal medicine, Surgery, Cardiology, Endocrinology

Related papers

Back to paper searchBrowse research topicsOriginal source
Cholesterol in fingerstick capillary specimens can be equivalent to conventional venous measurements. — Research Paper | ScholarLens