Cholesterol in fingerstick capillary specimens can be equivalent to conventional venous measurements.
G R Warnick, Elizabeth Teng Leary, Enrico Ammirati, Morrette Allen
Abstract
G R Warnick, Elizabeth Teng Leary, Enrico Ammirati, Morrette Allen
Abstract
Current interest in coronary heart disease and cholesterol has led to the development of a new generation of compact analysis systems designed for fingerstick whole blood measurement. Since reliable classification of patients based on national cut-points for serum cholesterol concentration requires accurate results, the question whether results from fingerstick capillary specimens are equivalent to those from conventional venous-derived serum specimens, the basis for the national cut-points, is germane. Earlier studies in the literature are contradictory, with fingerstick differences ranging from 9% low to 6% high. We developed guidelines for reliable fingerstick collection and, following these guidelines, achieved results that were comparable to results derived from concurrently collected venous serum specimens. Results measured either by an accurate, standardized enzymatic assay or by the AccuMeter, a new noninstrumented device, were in close agreement with serum results, ie, within 1% and 1.7%, respectively, suggesting that fingerstick measurements are appropriate for identifying individuals with elevated cholesterol levels and monitoring their treatment.
OpenAlex reports 23 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Current interest in coronary heart disease and cholesterol has led to the development of a new generation of compact analysis systems designed for fingerstick whole blood measurement. Since reliable classification of patients based on national cut-points for serum cholesterol concentration requires accurate results, the question whether results from fingerstick capillary specimens are equivalent to those from conventional venous-derived serum specimens, the basis for the national cut-points, is germane. Earlier studies in the literature are contradictory, with fingerstick differences ranging from 9% low to 6% high. We developed guidelines for reliable fingerstick collection and, following these guidelines, achieved results that were comparable to results derived from concurrently collected venous serum specimens. Results measured either by an accurate, standardized enzymatic assay or by the AccuMeter, a new noninstrumented device, were in close agreement with serum results, ie, within 1% and 1.7%, respectively, suggesting that fingerstick measurements are appropriate for identifying individuals with elevated cholesterol levels and monitoring their treatment.
Key concepts: Fingerstick, Medicine, Venous blood, Cholesterol, Internal medicine, Surgery, Cardiology, Endocrinology