Thermionic cooling with functionalized carbon nanotube thin films
Feng Jin, Scott Little
Abstract
Feng Jin, Scott Little
Abstract
A large thermionic cooling effect is reported. Temperature reduction as much as 81 °C has been observed on a functionalized carbon nanotubes (CNTs) cathode surface. This cathode utilizes a thin coating of low work function barium strontium oxide emissive materials on top of the CNTs to lower the surface work function. This, combined with the field effect induced by the CNTs, results in an even lower effective work function, and thus strong thermionic emission. Strong thermionic emission is the underlying reason for the large cooling effect observed, and the largest emission current in this study is around 160 mA on a 0.0727 cm2 emitting surface at around 995 °C. Multiple samples were used in studying thermionic mission at cathode temperature ranging between 750 °C and 1100 °C, and in establishing correlation between the cooling effect and the emission current. Details of the cooling effect measurement are provided, and the measurement results show a clear linear dependence of temperature drop on thermionic emission current. The possible implication of this linear dependence is also discussed.
OpenAlex reports 10 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A large thermionic cooling effect is reported. Temperature reduction as much as 81 °C has been observed on a functionalized carbon nanotubes (CNTs) cathode surface. This cathode utilizes a thin coating of low work function barium strontium oxide emissive materials on top of the CNTs to lower the surface work function. This, combined with the field effect induced by the CNTs, results in an even lower effective work function, and thus strong thermionic emission. Strong thermionic emission is the underlying reason for the large cooling effect observed, and the largest emission current in this study is around 160 mA on a 0.0727 cm2 emitting surface at around 995 °C. Multiple samples were used in studying thermionic mission at cathode temperature ranging between 750 °C and 1100 °C, and in establishing correlation between the cooling effect and the emission current. Details of the cooling effect measurement are provided, and the measurement results show a clear linear dependence of temperature drop on thermionic emission current. The possible implication of this linear dependence is also discussed.
Key concepts: Thermionic emission, Work function, Materials science, Cathode, Hot cathode, Carbon nanotube, Field electron emission, Cold cathode