1995CORROSIONRequires access

Localized Cathodic Protection of Simulated Prestressed Concrete Pilings in Seawater

Olivier Chaix, W.H. Hartt, Richard J. Kessler, Rodney G. Powers

Open publisher page 11 citations

Abstract

Corrosion-induced deterioration of prestressed concrete pilings in seawater has been established as the predominant failure mode for bridge substructures in coastal Florida waters. A technology involving localized impressed-current cathodic protection (CP) of the splash-zone region in association with conductive rubber anodes was developed to mitigate this deterioration. A series of experiments involving cathodic polarization of simulated prestressed concrete piling specimens partially immersed in seawater was performed. Variables included the concrete mix design, specimen cross section, anode dimensions, and water level. An interactive aspect of CP-operating parameters in association with water level was identified as important if excessively negative potentials and possible tendon embrittlement were to be avoided. The data were evaluated with regard to the interdependence between depolarization magnitude, potential, and concrete relative humidity. Results were reviewed within the context of CP utility for prestressed concrete bridge piling.

About this research paper

What this paper is about

Corrosion-induced deterioration of prestressed concrete pilings in seawater has been established as the predominant failure mode for bridge substructures in coastal Florida waters. A technology involving localized impressed-current cathodic protection (CP) of the splash-zone region in association with conductive rubber anodes was developed to mitigate this deterioration. A series of experiments involving cathodic polarization of simulated prestressed concrete piling specimens partially immersed in seawater was performed. Variables included the concrete mix design, specimen cross section, anode dimensions, and water level. An interactive aspect of CP-operating parameters in association with water level was identified as important if excessively negative potentials and possible tendon embrittlement were to be avoided. The data were evaluated with regard to the interdependence between depolarization magnitude, potential, and concrete relative humidity. Results were reviewed within the context of CP utility for prestressed concrete bridge piling.

Why it matters

OpenAlex reports 11 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Corrosion-induced deterioration of prestressed concrete pilings in seawater has been established as the predominant failure mode for bridge substructures in coastal Florida waters. A technology involving localized impressed-current cathodic protection (CP) of the splash-zone region in association with conductive rubber anodes was developed to mitigate this deterioration. A series of experiments involving cathodic polarization of simulated prestressed concrete piling specimens partially immersed in seawater was performed. Variables included the concrete mix design, specimen cross section, anode dimensions, and water level. An interactive aspect of CP-operating parameters in association with water level was identified as important if excessively negative potentials and possible tendon embrittlement were to be avoided. The data were evaluated with regard to the interdependence between depolarization magnitude, potential, and concrete relative humidity. Results were reviewed within the context of CP utility for prestressed concrete bridge piling.

Key concepts: Cathodic protection, Seawater, Corrosion, Prestressed concrete, Galvanic anode, Materials science, Metallurgy, Environmental science