Variation of left ventricular myocardial gray level on two-dimensional echocardiograms as a result of cardiac contraction.
Brian Olshansky, Stephen Michael Collins, David J. Skorton, N. V. Prasad
Abstract
Brian Olshansky, Stephen Michael Collins, David J. Skorton, N. V. Prasad
Abstract
Integrated ultrasonic backscatter from normal myocardium has been shown to vary with the phase of cardiac contraction (decreasing from end-diastole to end-systole) in previous studies of open-chest dogs. If confirmed, this finding would have important implications for clinical application of ultrasonic tissue characterization. Our hypothesis was that a cardiac cycle-dependent variation in regional average gray level would be detected on analysis of digitized two-dimensional echocardiograms. We analyzed echocardiographic images from 16 subjects in whom normal, technically good studies were obtained with a commercial phased-array scanner and a 2.25 MHz transducer. Images from six subjects were digitized from stop-frame photographs and those from 10 subjects were obtained directly in digital format from the scanner. Average gray level was measured in a portion of the left ventricular posterior wall in parasternal long-axis images obtained at end-diastole and end-systole by both photographic and digital-image acquisition. In seven of the subjects from whom digital images were acquired, left ventricular posterior wall gray level and ventricular septal gray level were also evaluated on parasternal short-axis images. In images digitized by the photographic technique, mean posterior wall gray level decreased significantly from end-diastole (175 +/- 5.8 SEM) to end-systole (167 +/- 5.1, p less than .05). Similarly, in images digitized directly, mean posterior wall gray level in the long-axis view decreased from end-diastole (71 +/- 3.4) to end-systole (59 +/- 2.5, p less than .005).(ABSTRACT TRUNCATED AT 250 WORDS)
OpenAlex reports 64 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Integrated ultrasonic backscatter from normal myocardium has been shown to vary with the phase of cardiac contraction (decreasing from end-diastole to end-systole) in previous studies of open-chest dogs. If confirmed, this finding would have important implications for clinical application of ultrasonic tissue characterization. Our hypothesis was that a cardiac cycle-dependent variation in regional average gray level would be detected on analysis of digitized two-dimensional echocardiograms. We analyzed echocardiographic images from 16 subjects in whom normal, technically good studies were obtained with a commercial phased-array scanner and a 2.25 MHz transducer. Images from six subjects were digitized from stop-frame photographs and those from 10 subjects were obtained directly in digital format from the scanner. Average gray level was measured in a portion of the left ventricular posterior wall in parasternal long-axis images obtained at end-diastole and end-systole by both photographic and digital-image acquisition. In seven of the subjects from whom digital images were acquired, left ventricular posterior wall gray level and ventricular septal gray level were also evaluated on parasternal short-axis images. In images digitized by the photographic technique, mean posterior wall gray level decreased significantly from end-diastole (175 +/- 5.8 SEM) to end-systole (167 +/- 5.1, p less than .05). Similarly, in images digitized directly, mean posterior wall gray level in the long-axis view decreased from end-diastole (71 +/- 3.4) to end-systole (59 +/- 2.5, p less than .005).(ABSTRACT TRUNCATED AT 250 WORDS)
Key concepts: Parasternal line, Medicine, Cardiac cycle, Diastole, Systole, Gray level, Cardiology, Posterior wall